Chapter 94- Basic Fittings For Hot Water Boilers Flashcards

1
Q

The following fittings are required on every hot water boiler

A
Pressure or altitude gauge
Thermometer
Safety relief valve 
Temps true relief device
Stop valve
Blow off or drain connection
Expansion tank
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In order to indicate the working pressure in hot water boilers, each hot water boiler shall be equipped with a

A

Pressure or altitude gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In what manner must a pressure or altitude gauge be connected to a hot water boiler

A

In such a manner that it cannot be shut off, except by a cock with a tee or lever handle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The scale on a gauge must be graduated to what specifications

A

Not less than 1 1/2 or more than 3 times the maximum allowable working pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many pointers does an altitude gauge have?

A

2

One for water height one for pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does it mean if the water pressure reading is lower than the water height reading?

A

The boiler is no longer full of water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A safety relief valve is used for

A

Steam pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A pressure relief valve is used for

A

Liquid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What may be installed between a pressure relief valve and the boiler?

A

Absolutely fucking nothing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The discharge piping from a safety relief valve must be connected how

A

It can’t be connected directly there must be an air break

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What’s an expansion tank

A

To provide storage space for excess water due to thermal expansion

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A pressure or altitude gauge for a hot water boiler does not require a

A

Siphon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In a hot water boiler heating system when the system is cold

A

The auto fill valve will maintain a system minimum pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The temperature indicator of a hot water boiler should indicate water temperature

A

At the boiler outlet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hot water heating boilers must be equipped with a

A

Thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A boiler pressure relief valve

A

Are usually installed on the boiler

17
Q

For hot water bless operating up to 414 Kpa, a pressure relief valve opening pressure variation may be as much as

A

20 Kpa

18
Q

A hot water boiler is protected from over pressure by means of

A

A safety relief valve

19
Q

Hot water boilers have stop valves in there inlet and outlet piping

A

S that the oiler may be drained without draining the system

20
Q

Boiler stop valves shall be

A

Identifiable with durable tags

21
Q

During warmup of a cold water boiler excessive pressure buildup is prevented with

A

An expansion tank

22
Q

The air released from the water in the closed expansion tank type hot water heating system is directed to

A

The expansion tank

23
Q

In a closed expansion tank system, an air separator

A

Directs air into the expansion tank

24
Q

In a hot water heating system the closed type expansion tank should be

A

Partly filled with water

25
Q

When a closed type expansion tank on a hot water boiler is completely filled with water and the water in the system is raised in temperature so that it expands, the result will be that

A

The pressure build up opens the safety relief device

26
Q

An expanse tank is used to

A

Allow for the expansion of the water

27
Q

A closed expansion tank is usuall equipped with

A

A gauge glass

28
Q

How are stop valves which are used on steam outlet connections of heating boilers identified?

A

With metal tags

29
Q

An automatic fill valve

A

Is not mandatory

30
Q

The following fittings are desired but not required on hot water heating boilers

A

Air separator
Automatic fill valve
Circulating pump

31
Q

In hot water heating boiler systems the gauge glasses are normally fitted to the

A

Expansion tank