Chapter 8 Quiz Flashcards

1
Q

Which term describes the useful area of a digital image receptor?

a.) FOV
b.) VOI
c.) ROI
d.) VOF

A

a.) FOV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

_____________ imaging uses barium fluorobromide or cesium bromide for photon absorption.

a.) direct DR
b.) indirect DR
c.) CR

A

c.) CR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

_______________ compression is recoverable and does not compromise image quality.

a.) lossless
b.) lossy

A

a.) lossless

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

WHich of the following are components of a CR system? (choose all that apply)

a.) workstation
b.) reader
c.) dry laser printer
d.) image receptor

A

a.) workstation
b.) reader
d.) image receptor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Digital fluoro equipment should be tested every __________

a.) week
b.) year
c.) 6 months
d.) month

A

c.) 6 months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A SMPTE pattern is best used to evaluate:
1.) dry laser printers
2.) electronic display devices
3.) image intensifiers
4.) DICOM systems

a.) 2 only
b.) 1 and 2
c.) 1, 2, 4
d.) 3 only

A

b.) 1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A ___________ uses a computer chip instead of a photoconductor target.

a.) plumbicon
b.) orthicon
c.) vidocon
d.) CCD

A

d.) CCD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Error correction tests should be performed by the:

a.) service engineer
b.) QC technologist
c.) physicist
d.) technologist

A

a.) service engineer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the disadvantages of DR? (choose all that apply)

a.) backscatter
b.) dropped pixels
c.) electronic noise
d.) lower SNR

A

a.) backscatter
b.) dropped pixels
c.) electronic noise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

WHen is a coupling element needed in DR?

a.) when using a direct capture IR
b.) when using a indirect capture IR
c.) when used with an amorphous silicon photodetector
d.) when used with an amotphous selenium photoconductor

A

b.) when using an indirect capture IR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A DEL is also known as a :

a.) CCD
b.) AMA
c.) TFT
d.) pixel

A

d.) pixel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which of the following describes a health record that covers the full range of a patients health history?

a.) RIS
b.) EHR
c.) EMR
d.) HIS

A

b.) EHR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The ability to resolve relatively large objects with similar density is called:

a.) high contrast resolution
b.) low contrast resolution
c.) flux gain
d.) magnification

A

b.) low contrast resolution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The ability to resolve relatively large objects with similar density is called:

a.) high contrast resolution
b.) low contrast resolution
c.) flux gain
d.) Minification

A

b.) low contrast resolution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which fluoroscopy mode results in higher patient dose because it films in multiple frames per second?

a.) continuous
b.) pulsed interlaced
c.) slow scan
d.) pulsed progressive

A

a.) continuous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

WHat is the primary factor that influences contrast in a digital image?

a.) kvp
b.) mas
c.) rescaling
d.) look up table (LUT)

A

d.) Look up table (LUT)

17
Q

WHen exposing the second image in a series of xrays any residual TFT charge could result in :

a.) histogram error
b.) fading
c.) erasure
d.) ghosting

A

d.) ghosting

18
Q

Amorphous silicon and cesium iodide is used in:

a.) CR imaging
b.) direct DR Imaging
c.) indirect DR Imaging

A

c.) Indirect DR Imaging

19
Q

The most common types of electronic display devices used today are:
1.) CRT
2.) HD
3.) LCD
4.) Plasma

a.) 1 only
b.) 1, 3, 4
c.) 3 and 4
d.) 2, 3, 4

A

b.) 1, 3, 4

20
Q

A semiannual or annual QC test would be:
1.) generator testing
2.) film processor maintenance if hard copies are printed
3.) clean CRT screen monitors
4.) evaluate exposure indicator accuracy

a.) 1 and 4
b.) 2, 3 and 4
c.) 1 only
d.) 2 and 3

A

a.) 1 and 4

21
Q

Which of the following is NOT true of lossy compression

a.) compromises image quality
b.) cannot be reversed
c.) data is recoverable
d.) data can be compressed to 5 to 50 times

A

c.) data is recoverable