Chapter 7 Waste Flashcards
Exposed soil or waste piping shall not be installed _______ any working ,storage or eating surfaces in a food service establishment.
Above. 701.9
2 1/2 inch or less horizontal drainage pipe shall slope a minimum of ______ inch per foot.
1/4 in. Table 704.1
The size of the drainage piping shall not be ________ in size in the direction of flow.
Reduced
A 4” x 3” water closet connection is okay. 704.2
Pipe-joint compound or tape shall be applied on the _______ threads only.
Male 705.12.1
All horizontal drains shall be provided with cleanouts located not more than_______ feet apart.
100ft
And at each change of direction greater than 45
708.3.1
Cleanouts shall be the same nominal size as the pipe they serve up to _______ inches.
4”
708.7
Cleanouts on 6” and smaller pipes shall be provided with a clearance of not less than ____ inches in front of the cleanout.
18”
708.8
The minimum trap size for unlisted fixtures shall be the size of the drainage outlet but not less than______ inches.
1 1/4 “
709.2
Sump pits shall be not less than ___ inches in diameter and 24 inches deep.
18 inch
712.3.2
A floor drain installed a public restroom with a 3” trap has a DFU of what?
5DFU’s
Table 709.1
The minimum size of a building drain or sewer that serve a water closet?
3 inch
Table 710.1(1) footnote
Where the finished floor level on which plumbing fixtures are installed is below the elevation of the manhole cover of the next upstream manhole,the fixtures shall be protected by a ______.
Backwater valve
715.1
When make a solvent cement joint on PVC pipe the primer shall be of what color?
Purple
705.8.2 ; 705.14.2
What valves shall be installed in the discharge of a sewage ejector pump ?
Check valve ; a full open valve
712.2
A sewage ejector discharge line that ties into a horizontal drainage line shall do ____ pipe diameters from any other connection and shall do so through a ___ fitting into the top of the drainage piping.
10 pipe diameters ; a wye fitting
712.3.5
The minimum size trap serving a shower shall be not less than ____.
1 1/2”
Table 709.1
The maximum waste water temperature that discharges into the drainage system?
140 degrees F
701.7
The DFU value for the discharge from a condensate pump is computed how?
1gpm equals 2DFU’s
709.3
Joints between borosilicate glass pipe and others of piping materials shall have what type of seal?
TFE ( Teflon)
705.19.6
When the DFU load of a fixture is not found in table 709.1 , how is the DFU load calculated?
By trap size
709.2 ; Table 709.2