Chapter 3 General Regulations Flashcards
What is permitted to discharge into gray water system?
bathtubs,showers,clothes washer & laundry tray
301.3 exception
Where there is a conflict between the code & manufactures installation instructions,which one do you follow?
The more restrictive
301.7
A sump pump is permitted at the base of an elevator shaft when the discharge is connected to the drainage system in what manor?
indirectly to the system
301.6 exception
What is minimum burial depth of exterior water service piping ?
12”
305.4
The code does not permit the use of ____to support & maintain the grade of drainage piping in a trench.
Blocks
306.2
Shield plates required to protect piping installed through notches or bored holes in framing members shall extend a minimum_____ inch(es) above sole plates & below top plates.
2”
307.5