Chapter 7 Flashcards

1
Q

Which of the following statements about pump discharge pressure is MOST accurate?

A

Pump discharge pressure must be sufficient to overcome all pressure loss.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which of the following BEST describes friction loss for handlline nozzles?

A

Generally considered to be insignificant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The pump discharge pressure should be calculated and set based on:

A

hoseline with the greatest pressure requirement.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When determining pressure loss for elevated waterways, the elevation of the master stream:

A

must be considered as part of the total pressure loss.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which method of determining friction loss relies on the use of mathematical equations or field application methods?

A

Using calculations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Total pressure loss includes friction loss and elevation pressure loss combined with the loss associated with:

A

appliances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In the formula for friction loss, the “L” refers to:

A

hose length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which of the following is a friction loss guideline in a hose assembly when flowing 350 gpm (1 400 L/min) or greater?

A

There is a loss of 10 psi (70 kPa) for each appliance, other than master stream devices.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which method of determining friction loss involves the use of in-line gauges to measure friction loss at various flows through specific hose layouts?

A

Performing tests

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following customary formulas would be used to determine elevation pressure in a multistory building?

A

5 psi × (number of stories - 1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When a pumper is being supplied by another pumper, net pump discharge pressure is the difference between pump discharge pressure and:

A

incoming pressure from supply source.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which of the following is the correct formula for Net Pump Discharge Pressure?

A

Pump Discharge Pressure - Intake Reading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

To calculate friction loss when using multiple hoselines of unequal length, a driver/operator must:

A

calculate friction loss for each hoseline supplied by separate discharges to individual nozzles.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which of the following is the correct customary formula for determining pump discharge pressure?

A

Nozzle pressure plus total pressure loss

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following BEST describes friction loss for master stream appliances?

A

25 psi (175kPa) for all appliances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When using multiple hoselines of equal length and diameter, loss calculations:

A

need only be made for one line.

17
Q

If a jurisdiction is performing tests using equipment they own in order to achieve more accurate results, the testing should be conducted:

A

using actual hose that will be used during firefighting operations.

18
Q

The current formula for friction loss accounts for the diameter of the hose, the volume of water flowing, and the:

A

length of the hose layout.

19
Q

Which of the following statements about adding unequal lengths of hose to an established wyed hose layout is MOST accurate?

A

Friction loss must be determined for each attack line.

20
Q

Which of the following customary formulas would be used to conduct elevation pressure loss calculations on the fireground?

A

0.5 × Height in feet

21
Q

Which of the following is the primary consideration for friction loss?

A

Volume of water flowing per minute GPM

22
Q

When two hoselines of equal length are Siamesed to supply a fire stream, friction loss is approximately:

A

25 percent less than that of a single hoseline at the same nozzle pressure.

23
Q

The use of standard formulas and field applications for determining friction loss are generally:

A

relied upon for safe fireground operations.

24
Q

When using multiple hoselines of equal length but different diameter, loss calculations:

A

must be made for both lines.

25
Q

When determining friction loss in a wyed hoseline in which the hoselines have the same nozzle pressure, hose length, and diameter:

A