Chapter 6 - specific appliances Flashcards

1
Q

The design of the installation shall include adequate provision to permit, direct fired industrial air heaters to operate at rated capacity by taking into account the structures, design, infiltration rate, providing properly design, relief openings, or an interlock power exhaust system or a:

A

or a combination of these methods

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Dryer exhaust systems shall be _____ of all other systems, and shall convey the moisture, and any products of combustion to the outside of the building.

A

Independent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Ducts that exhaust clothes dryers shall not penetrate or be located within any fire blocking, draft stopping or any wall, flooring or ceiling or other assembly required by the international building code unless duct is constructed of

A

Galvanized steel, or aluminum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Dryer installations exhausting more than ____ a minute shall be provided with make up air.

A

200 ft.³

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where a closet is designed for the installation of a clothes, dryer, an opening having an area of not less than ________ shall be provided in the closet enclosure, or make up air shall be provided by other approve means

A

100 in.²

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Dryer duct shall be a minimum of what size

A

4 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Dryer ducts shall have a smooth interior finish and shall be constructed of metal not less than:

A

0.016 inches thick

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Transition ducts shall not be more than_____ long

A

8 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The maximum length of the dryer exhaust duct shall be:

A

35 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where the dryer exhaust duct equivalent length exceeds 35 feet, the equivalent length of the exhaust duct shall be identified on a permanent label or tag located within _____ of the exhaust duct

A

6 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Sauna heater shall be equipped with a thermostat that will limit room temperature to:

A

194°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If the thermostat is not an integral part of the sauna heater, the heat sensing element shall be located within

A

6 inches of the ceiling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The letters indicating the harmful effects of the sauna for any persons and pour house shall be how tall

A

Not less than 1/4 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Outdoor air inlets for residential portions of a building shall be covered with a screen, having what size openings?

A

1/4 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Suspended type unit heaters shall be installed with clearances to combustible materials not less than_____ on the sides

A

18 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Suspended type unit heater shall be installed with a clearance to combustibles of not less than _____ at the bottom

A

12 inches

17
Q

Suspended type unit heater shall be installed with clearance to combustibles of not less than _____ above the top where the unit heater has an internal draft hood

A

6 inches

18
Q

Unvented room heaters shall be equipped with

A

Oxygen depletion – sensitive safety shut off systems

19
Q

For oxygen depletion sensitive shut off systems, the system shall shut off a gas supply to the main pilot burner when the oxygen in the surrounding atmosphere is depleted to the percentage, concentration specified by the manufacturer, but not lower than

A

18%

20
Q

The oxygen depletion sensitive safety shut off. System shall not incorporate field adjustment means capable of.

A

Changing the setpoint

21
Q

A minimum clearance of _____ shall be maintained between the cooking top and combustion materials above the hood.

A

24 inches

22
Q

The minimum width of a cooktop hood should be

A

As wide as the cooktop itself

23
Q

Means for interrupting the electrical supply to the air-conditioning appliance and it’s associated cooling tower in a location remote from the air conditioner shall be provided with insight and not over

A

50 feet from the air conditioner

24
Q

When unvented, infrared heaters are installed, natural, or mechanical means shall provide an outdoor ventilation air at a rate of not less than

A

Four CFM per 1000 BTU of the aggregate input rating of all such heaters installed in the space

25
Q

For all infrared heaters exhaust openings for removing flue products shall be

A

Above the level of the heaters

26
Q

For gaseous hydrogen systems, piping shall not be installed in or through

A

A circulating air duct, clothes, shoot, chimney, or gas vent, ventilating, duck, dumbwaiter, or elevator shaft

27
Q

For gashes hydrogen systems piping shall not be concealed by the surface of

A

Any wall or ceiling

28
Q

For a floor furnace, the lowest part must have at least a 12-inch clearance on every side but the control side, which must have a clearance of at least ______ inches.

A

18”

29
Q

Unvented infrared heaters require an outdoor air-ventilation rate of at least ______ cfm per 1,000 BTU/h of aggregate input rating.

A

4 cfm

Section 630 Infrared Radiant Heaters 630.3 (IFGS) Combustion and ventilation air

30
Q

A wall furnace may not have casing extension boots installed unless:

A

Listed as part of the appliance.

608.5 Ducts prohibited.

31
Q

A way to supply outside ventilation at a rate of at least ________ per 1,000 BTU/h of rated input of the heater must be incorporated into direct-fired industrial air heaters.

A

4 cubic feet per minute

32
Q

A way to supply outside ventilation at a rate of at least ________ per 1,000 BTU/h of rated input of the heater must be incorporated into direct-fired industrial air heaters.

A

4 cubic feet per minute

33
Q

A sauna room is required to have a permanent notice outside warning users that the maximum time in the sauna is ______ minutes.

A

30

34
Q

An air-conditioning appliance must have a means to interrupt the electricity, a maximum of ______ from the appliance and within sight.

A

50