Drinking fountains shall have a clear floor or ground space of ____ inches minimum by ____ inches minimum positioned for a _______ approach and ________ on the unit.
30 INCHES, 48 INCHES, FORWARD, CENTERED
602.2 Drinking Fountains, Clear Floor Space - Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with 306 shall be provided.
____ and ___ clearance complying with 306 shall be provided.
KNEE, TOE
602.2 Drinking Fountains, Clear Floor Space - Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with 306 shall be provided.
A ________ approach complying with 305 shall be permitted at units for __________ use where the spout is ____ inches maximum above the finish floor or ground and is _____ inches maximum from the front edge of the unit, including bumpers.
PARALLEL, CHILDREN’S, 30 INCHES, 3 1/2 INCHES
602.2 Drinking Fountains, Clear Floor Space - Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit. Knee and toe clearance complying with 306 shall be provided.
EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3 1/2 inches (90 mm) maximum from the front edge of the unit, including bumpers.
Drinking fountain operable parts shall not require _____ ________, ________, or ________ __ ___ _____.
TIGHT GRASPING, PINCHING, TWISTING OF THE WRIST
602.3 Drinking Fountains, Operable Parts - Operable parts shall comply with 309.
Drinking fountain spout outlets shall be ____ inches maximum above the finish floor or ground.
36 INCHES
602.4 Drinking Fountains, Spout Height - Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
The spout for drinking fountains shall be located ____ inches minimum from the vertical support and ____ inches maximum from the front edge of the unit, including bumpers.
15 INCHES, 5 INCHES
602.5 Drinking Fountains, Spout Location - The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers.
The drinking fountain spout shall provide a flow of water ____ inches high minimum and shall be located ____ inches maximum from the front of the unit.
4 INCHES HIGH, 5 INCHES MAXIMUM
602.6 Drinking Fountains, Water Flow - The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall be measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (75 mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 inches (75 mm) and 5 inches (125 mm) maximum from the front of the unit, the angle of the water stream shall be 15 degrees maximum.
The angle of the water stream shall be measured ____________ relative to the front face of the unit.
HORIZONTALLY
602.6 Drinking Fountains, Water Flow - The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall be measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (75 mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 inches (75 mm) and 5 inches (125 mm) maximum from the front of the unit, the angle of the water stream shall be 15 degrees maximum.
Where drinking fountain spouts are located less than ____ inches of the front of the unit, the angle of the water stream shall be ____ degrees maximum.
3 INCHES, 30 DEGREES MAXIMUM
602.6 Drinking Fountains, Water Flow - The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall be measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (75 mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 inches (75 mm) and 5 inches (125 mm) maximum from the front of the unit, the angle of the water stream shall be 15 degrees maximum.
Where drinking fountain spouts are located between ____ inches and ____ inches maximum from the front of the unit, the angle of the water stream shall be ____ degrees maximum.
3 INCHES, 5 INCHES, 15 DEGREES
602.6 Drinking Fountains, Water Flow - The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall be measured horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (75 mm) of the front of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 inches (75 mm) and 5 inches (125 mm) maximum from the front of the unit, the angle of the water stream shall be 15 degrees maximum.
Spout outlets of drinking fountains for standing persons shall be ____ inches minimum and ____ inches maximum above the finish floor or ground.
38 INCHES MINIMUM, 43 INCHES MAXIMUM
602.7 Drinking Fountains for Standing Persons - Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the finish floor or ground.
Toilet and bathing rooms shall provide turning space complying with ___ within the room.
304
603.2.1 Toilet and Bathing Rooms, Turning Space - Turning space complying with 304 shall be provided within the room.
T /F - Within toilet and bathing rooms, required clear floor spaces, clearance at fixtures, and turning space shall not be permitted to overlap.
FALSE
603.2.2 Toilet and Bathing Rooms, Overlap - Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap.
Doors shall not swing into the _____ _____ _____ or clearance required for any _______.
CLEAR FLOOR SPACE, FIXTURE
603.2.3 Toilet and Bathing Rooms, Door Swing - Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space.
Doors shall be permitted to swing into the required _______ _____.
TURNING SPACE
603.2.3 Toilet and Bathing Rooms, Door Swing - Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space.
Doors to a toilet room or bathing room for a single occupant accessed only through a _______ ______ and not for common use or public use shall be permitted to swing into the clear floor space or clearance provided the swing of the door can be ________ to comply with 603.2.3.
PRIVATE OFFICE, REVERSED
603.2.3 Toilet and Bathing Rooms, Door Swing - Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space.
EXCEPTIONS:
1. Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor space or clearance provided the swing of the door can be reversed to comply with 603.2.3.
2. Where the toilet room or bathing room is for individual use and a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space or clearance required for any fixture.
Where the toilet room or bathing room is for individual use and a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing, doors shall be _________ to swing into the clear floor space or clearance required for any fixture.
PERMITTED
603.2.3 Toilet and Bathing Rooms, Door Swing - Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space.
EXCEPTIONS:
1. Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor space or clearance provided the swing of the door can be reversed to comply with 603.2.3.
2. Where the toilet room or bathing room is for individual use and a clear floor space complying with 305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space or clearance required for any fixture.
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface ____ inches maximum above the finish floor or ground.
40 INCHES MAXIMUM
603.3 Toilet and Bathing Rooms, Mirrors - Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground.
Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface ____ inches maximum above the finish floor or ground.
35 INCHES MAXIMUM
603.3 Toilet and Bathing Rooms, Mirrors - Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground.
Coat hooks shall be located within one of the _____ ______ specified in 308.
REACH RANGES
603.4 Toilet and Bathing Rooms, Coat Hooks and Shelves - Coat hooks shall be located within one of the reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor.
Shelves shall be located ____ inches minimum and ____ inches maximum above the finish floor.
40 INCHES MINIMUM, 48 INCHES MAXIMUM
603.4 Toilet and Bathing Rooms, Coat Hooks and Shelves - Coat hooks shall be located within one of the reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor.
T / F - Water closets and toilet compartments for children’s use shall be permitted to comply with dimensions shown in 604.9.
TRUE
604.1 Water Closets and Toilet Compartments, General - Water closets and toilet compartments shall comply with 604.2 through 604.8.
EXCEPTION: Water closets and toilet compartments for children’s use shall be permitted to comply with 604.9.
At water closets and toilet compartments serving children ages 3 and 4, the water closet centerline shall be ____ inches.
12 INCHES
604.1 Water Closets and Toilet Compartments, General - Water closets and toilet compartments shall comply with 604.2 through 604.8.
EXCEPTION: Water closets and toilet compartments for children’s use shall be permitted to comply with 604.9.
At water closets and toilet compartments serving children ages 5 through 8, the water closet centerline shall be between ____ inches and ____ inches.
12 INCHES, 15 INCHES
604.1 Water Closets and Toilet Compartments, General - Water closets and toilet compartments shall comply with 604.2 through 604.8.
EXCEPTION: Water closets and toilet compartments for children’s use shall be permitted to comply with 604.9.