Chapter 4: Plumbing Fixtures And Fixture Fittings Flashcards
Screws or bolts for securing floor-mounted fixtures shall be __________
Copper alloy
Fixtures having concealed slip-joint connections shall be provided with a utility space or __________
Access panel
The overflow pipe from a fixture shall be connected on the house or __________ side of the fixture trap
Inlet
The diameter of a waste outlet and fixture tailpiece for a bathtub shall not be less than __________
1-1/2” in diameter
The fitting indicated by the arrow shall be a(an) __________
D) B&C
(Directional type branch, approved wye)
The connection of the dishwasher drain directly to the continuous waste, as indicated by the arrow, is __________
A code violation
No dry or chemical closet (toilet) shall be installed in any building used for human habitation unless first approved by the __________
Health officer
The distance X shall not be less than __________
15 inches
The distance Y shall not be less than __________
24 inches
Tanks flushing more than one urinal shall be __________
Automatic in operation
A water supply to a urinal shall be protected by an approved __________
B) Vacuum breaker
Trough urinals shall be __________
Prohibited
With two noted exceptions, all shower compartments and receptors shall be capable of encompassing a __________ diameter circle.
30 inch
Exceptions:
1. Showers that are designed to be in accordance with ICC A117.1
2. The minimum required area and dimension shall not apply for a shower receptor having overall dimensions of not less than 30 inches in width and 60 inches in length
The curb or threshold of a shower compartment is required for __________
D) none of the above
If provided with a threshold or curb, distance x shall not be less than __________ or exceed __________.
A) 2 inches, 9 inches
Shower pan linings may be constructed with __________
15 pounds asphalt felt