Chapter 4: Plumbing Fixtures And Fixture Fittings Flashcards
Screws or bolts for securing floor-mounted fixtures shall be __________
Copper alloy
Fixtures having concealed slip-joint connections shall be provided with a utility space or __________
Access panel
The overflow pipe from a fixture shall be connected on the house or __________ side of the fixture trap
Inlet
The diameter of a waste outlet and fixture tailpiece for a bathtub shall not be less than __________
1-1/2” in diameter
The fitting indicated by the arrow shall be a(an) __________
D) B&C
(Directional type branch, approved wye)
The connection of the dishwasher drain directly to the continuous waste, as indicated by the arrow, is __________
A code violation
No dry or chemical closet (toilet) shall be installed in any building used for human habitation unless first approved by the __________
Health officer
The distance X shall not be less than __________
15 inches
The distance Y shall not be less than __________
24 inches
Tanks flushing more than one urinal shall be __________
Automatic in operation
A water supply to a urinal shall be protected by an approved __________
B) Vacuum breaker
Trough urinals shall be __________
Prohibited
With two noted exceptions, all shower compartments and receptors shall be capable of encompassing a __________ diameter circle.
30 inch
Exceptions:
1. Showers that are designed to be in accordance with ICC A117.1
2. The minimum required area and dimension shall not apply for a shower receptor having overall dimensions of not less than 30 inches in width and 60 inches in length
The curb or threshold of a shower compartment is required for __________
D) none of the above
If provided with a threshold or curb, distance x shall not be less than __________ or exceed __________.
A) 2 inches, 9 inches
Shower pan linings may be constructed with __________
15 pounds asphalt felt
Joints in copper shower pan liners shall be __________
Soldered or brazed
Drinking fountains shall not be installed in __________
Public toilet rooms
Water closets set side by side shall be no closer than __________
D) 30 inches center-to-center
The minimum distance from a side wall or partition to the center of a urinal shall be __________ inches.
12 inches
Manually controlled flushometer valves shall be used to flush not more than __________
One urinal
The joint of a wall-hung lavatory, where it is in contact with the wall, shall be __________
D) made water tight
Approved type bonderized and galvanized sheet steel of not less than 16 U.S. gauge may be used to make dishwashing sinks for __________
A) restaurants
Gutters in public shower rooms shall be sloped not less than __________
C) 2 percent
Wall-hung lavatories shall be supported by __________
A) metal supporting members
The tailpiece diameters for lavatories shall not be less than __________
A) 1-1/4”
In the construction of “on-site built-up shower receptors” water tight shower pan linings shall be installed, over a smooth and solid sub-base, with a pitch to the “weep holes” of__________
B) 1/4 inch per foot
Strainers having waterway areas at least equivalent to the area of their tailpiece are required for __________
D) A&B
(Shower drains & floor drains)
Showers and tub-shower combinations shall be provided with individual limit control valves of the __________
D) A and B apply
(Pressure balance type & thermostatic mixing valve type)
The clear space in front of any water closet, lavatory or bidet shall not be less than __________
C) 24 inches
Non-water urinals __________
D) require individually roughed in water lines
Maximum hot water temperature discharging from a bidet shall be limited to __________
B) 110º F
Closet bends or stubs shall be cut off so as to present a smooth surface, even with the __________
B) top of the closet ring
Wall-mounted water closets shall be bolted to __________
C) a carrier fitting
Fixture connections between drainage pipes and water closets shall be made with approved __________
C) flanges
The water supply to a bathtub and whirlpool bathtub filler valve shall be protected by an __________ or in accordance with section 417.
Air gap
A domestic dishwashing machine shall discharge indirectly through an air gap fitting into a __________.
D) all of the above
The path of travel to an emergency eyewash shall be __________.
A) clearly identified
Supports for off the floor public use plumbing fixtures are to comply with ASME __________.
A) A112.6.1.M
An emergency eye wash supplied with hot and cold water shall be controlled by a temperature actuated mixing valve complying with ASSE __________.
D) 1071