Chapter 2: Definitions Flashcards

1
Q

A room equipped with a shower, bathtub or combination of bath/shower is a __________

A

Bathroom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fixture connections that require the removal of an access panel for servicing are considered __________

A

Accessible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

That part of the lowest piping of a drainage system that receives the discharge from soil, waste, and other drainage pipes inside the walls of the building and conveys it to a point 2 feet outside of the building wall is a __________

A

Building drain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A vertical vent that is a continuation of the drain to which it connects is a __________

A

Continuous vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A horizontal drain that is sized to provide free movement of air above the flow line of the drain is called a __________

A

Combination waste and vent system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The length along the centerline of the pipe and fittings is the __________

A

Developed length.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A device integrated within an air accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes is a(an)

A

Flushometer tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The combination of fittings that may be used to make an offset and is considered a vertical pipe are

A

1 - 45 degree and 1- 45 degree fitting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Water that is satisfactory for drinking, culinary and domestic purposes and that meets the requirements of the Authority Having Jurisdiction is referred to but this code as

A

Potable water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

By code definition, a stack is always

A

Vertical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A vent that also serves as a drain is a(an)

A

Wet vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A pipe that makes an angle of not more than 45 degrees with the vertical is considered

A

Vertical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The vertical depth of a trap seal is measured from

A

The crown weir to the top of the dip of the trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What word or term describes the sketch

A

Trap arm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What word or term fits the sketch

A

Private sewage disposal system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What word or term fits the sketch

A

Yoke vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What word or term fits the sketch

A

Sump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What word or term fits the sketch

A

Indirect waste pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What word or term fits the sketch

A

Grade of pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What word or term fits the sketch

A

Critical level marking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What word or term fits the sketch

A

airgap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What word or term fits the sketch

A

Horizontal Branch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What word or term fits the sketch

A

Wet vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

A mixing valve that senses outlet temperature and compensates for fluctuations in incoming hot or cold water temperature is a __________

A

Thermostatic (temperature control) valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

True or false: the restroom facilities in a private day care center are classified as public use.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

True or false: The discharge from clinical sinks and conveyed to the building drain is defined as a waste pipe

A

False.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

A combined building sewer is a __________

A

Building sewer that conveys both sewage and storm water

28
Q

Pex is defined as __________

A

Cross-linked polyethylene

29
Q

The lowest portion of the inside of a horizontal pipe is called the __________

A

Invert

30
Q

The part of the horizontal piping of a drainage system that begins __________ feet downstream from the last mobile home site and conveys it to a public sewer is called a mobile home park sewer.

A

2 feet

31
Q

True or false: A device and system of piping that maintains a water seal in a remote trap is called a trap primer.

A

True

32
Q

True or false: Static Pressure is pressure existing without any flow

A

True

33
Q

True or false: A permanently installed mechanical device, other than an ejector, for removing sewage or liquid waste from a sump is called a sewage pump

A

True

34
Q

A standard that is an extensive compilation of provisions covering broad subject matter is the definition for __________

A

Code

35
Q

The principal artery of the venting system to which branches may be connected is called the __________

A

Main Vent

36
Q

A joint obtained by the joining of metal parts with metallic mixtures or alloys that melt at a temperature up to an including 840°F is a __________

A

Soldered joint

37
Q

The organization, office, or individual responsible for enforcing the requirements of a code or standard is the __________

A

Authority Having Jurisdiction

38
Q

That portion of a drainage system that does not drain by gravity into the building Sewer is known as a __________

A

Building subdrain

39
Q

A pipe inside a building that conveys stormwater from the roof to a storm drain, combined building, sewer, or other other approved point of disposal is called a(an)

A

Conductor

40
Q

An outlet on a boiler to permit emptying or discharging of sediment is called a (an)

A

Boiler blowoff

41
Q

A device designed to provide protection against hydraulic shock in the building Water supply system is called a (an)

A

Water hammer arrestor

42
Q

A device installed in a drainage system to prevent reverse flow is a __________

A

Backwater valve

43
Q

Any pressure less than that exerted buy the atmosphere is a (an) __________

A

Vacuum

44
Q

A document, the main text of which contains only mandatory provisions using the word “shall” to indicate requirements, is best described as a __________ 

A

Standard

45
Q

A circuit vent connects to a horizontal drain branch and vents __________ traps and not more than __________ traps from a battery of fixtures.

A

2, 8

46
Q

When a backflow prevention device does not bear a critical level marking, the part of the device that shall constitute the critical level is the __________

A

Bottom

47
Q

A water heater is by definition and appliance for __________

A

Heating water to a maximum of 210°F

48
Q

The pipe or duct that connects a fuel– gas – burning water heater to a gas vent or chimney is a __________

A

Vent connector

49
Q

A water heater that is constructed and installed so that all air for combustion is derived directly from the outside atmosphere and all flue gases are discharged to the outside atmosphere is a (an)

A

Direct vent appliance

50
Q

Type B vent is used for venting a listed or approved appliance equipped to burn __________

A

Only gas

51
Q

The piping and equipment between the street gas main and the gas piping system inlet, which is installed by and is under the control of and maintenance of the serving gas supplier, is listed in the code as __________

A

Service piping

52
Q

Grounding electrodes are devices that establish an electrical connection to the __________

A

Earth

53
Q

SCFM stands for __________

A

Standard Cubic Feet per Minute.

54
Q

A valve that controls the gas or vacuum service to a particular area is a/an __________

A

Zone valve

55
Q

The pipe delivering potable water from the source of supply to a building or structure is the __________

A

Building supply

56
Q

The __________ serves Horizontal piping extending from a riser to a station outlet or inlet

A

service valve

57
Q

The T rating limits the maximum temperature rise of __________ above its initial temperature through the penetration on the non-fire side.

A

325º F

58
Q

The definition of __________ is: untreated wastewater that has not come into contact with toilet waste, kitchen sink waste, dishwasher waste, or similarly contaminated sources. This includes wastewater from bathtubs, showers, laboratories, clothes, washers, and laundry tubs.

A

Gray water

59
Q

Reclaimed water systems are defined as __________

A

Tertiary treated nonpotable water

60
Q

A device located at the bottom of the tank for the purposes of flushing water closets and similar fixtures is a __________

A

Flush valve

61
Q

Gray water is untreated waste water that has not come into contact with which of the following:
A. Showers
B. Tubs
C. Toilets
D. Lavatories

A

C. Toilets

62
Q

A physical separation that may be a low inlet into the indirect waste receptor from the fixtures, appliances, or devices indirectly connected is the definition for an __________

A

Airbreak

63
Q

A pipe that makes an angle of 45º from the vertical is considered ______

A

Vertical

64
Q

The definition for the word “stack” does not include __________

A

Water piping

65
Q

A medical gas system whose failure can cause minor injury to patients is defined as Category __________

A

2

66
Q

Air supplied from cylinders, bulk containers or reconstructed from oxygen USP is defined as Medical __________

A

Air