Chapter 23: Facility design, layout, and organization Flashcards

1
Q

first step to building a new facility

A

assemble a committee of professionals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

the committee should include the following (5)

A
contractor
architect
designer
lawyers
people involved in running the facility
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

4 phases of building a new facility

A

predesign
design
construction
preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

first step in building a new facility and should consist of a needs analysis, feasibility study and master plan

A

predesign phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

at the end of the predesign phase this individual should be hired

A

architect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

step in which designers and experts collaborate and determine the needs of the athletic program

A

needs analysis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

second part of the predesign phase

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

should analyze strengths, weaknesses, opportunites, and threats

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

the goal of this is to ensure that the financial investment will yield a viable and sustainable return

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

the general plan for all phases of the new facility

A

master plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

this is part of the master plan and sets long and short term goals, as well as staff development and hiring

A

operational plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

second phase in the process of building a new facility

A

design phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

this is one of the more important aspects of designing the facility

A

traffic flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

the blueprint is created during this phase

A

design phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

longest phase of the entire process

A

construction phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

final steps before the facility can open

A

preoperation phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

this phase includes finishing the interior décor and hiring a qualified staff

A

preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

various job duties, cleaning, clerical, and administrative are assigned

A

preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

recommended minimum amount of space per athlete is this much per participant

A

100 sqft or 9.3sqm

20
Q

the load bearing capacity of the building should be atleast this

A

100 lbs/sqft

21
Q

where should the supervision location be

A

central location with a clear line of sight and mirrors, may be elevated

22
Q

recommended ceiling height

A

12-14 ft

23
Q

temperature range for a facility

A

68-78* with 72-78* being ideal

24
Q

humidity should not exceed this %

A

60%

25
Q

air should be exchanged this often via HVAC, fresh air exchange system and fans

A

8-12 x/hour

26
Q

how many fans per 1200 sqft

A

2-4

27
Q

max speaker volume

A

90 decibels

28
Q

ideal speaker location

A

elevated an in the corners of the rooms

29
Q

Mirror placement

A

6 inches from any equipment and at least 20 inches from the floor

30
Q

how many phones are needed

A

at least 1 that is accessible to a person in a wheelchair

31
Q

minimum space between the ends of two barbells/barbell and dumbbells

A

36 inches

32
Q

distance between lifting equipment and weight trees

A

36 inches

33
Q

Racks should be placed here, unless this situation exists

A

against a wall, unless two racks are back to back

34
Q

space between racks and other equipment

A

36 inches

35
Q

width of walkways

A

36 inches

36
Q

these are the top priorites when one is deciding on placemtn of equipment in a facitiity

A

safety and function

37
Q

stretching and warmup space per athlete

A

49 sqft

38
Q

distance between circuit training machines

A

24-36(ideal) inches

39
Q

extra space for safety around equipment is called

A

a safety cushion

40
Q

any designated walkways in the circuit training area should be this wide

A

4-7ft

41
Q

this freeweight equipment similar to a dumbbell generally is used for dynamic movements and therefore requires more space

A

kettlebells

42
Q

racks and platfroms in the weightlifting area should be this far apart

A

3-4 ft

43
Q

space for bikes

A

24sqft

44
Q

space for stair steppers

A

24sqft

45
Q

space for skiers

A

6sqft

46
Q

space for rowers

A

40sqft

47
Q

space for treadmills

A

45 sqft