Chapter 2 UREs Flashcards
- (405) What Wing 3 and 5 LCC has no more than 10 storage batteries connected in series-parallel?
A. Squadron command post (SCP) LCC
B. Alternate command post (ACP) LCC
C. Wing command post (WCP) LCC
*D. Primary LCC
- (405) How many AC generators does the MAF MG have?
A. One
*B. Two
C. Three
D. Four
- (405) The battery charger for the MAF storage batteries is contained in the
A. motor generator.
*B. power supply group.
C. automatic switching unit.
D. diesel electric unit battery charger.
- (405) How are the storage batteries configured at all Wing 1 LCCs?
A. Twelve batteries connected in series
B. Sixteen batteries connected in series
C. Six pairs of batteries connected in series-parallel
*D. Eight pairs of batteries connected in series-parallel
- (406) What power output does the DEU produce at a Wing 3 and 5 LF in the event of a commercial power failure?
*A. 120/208 VAC, 3-phase, 60-Hz only
B. 120/208 VAC, 3-phase, 400-Hz and single-phase, 60-Hz only
C. 120/208 VAC, single-phase, 60-Hz only
D. 120/208 VAC, 3-phase, 400-Hz only
- (406) What component installed on the MAF MG is not installed on the LF MG?
A. AC motor
B. DC motor
C. 400 Hz AC generator
*D. 60 Hz AC generator
- (406) When the D-box connects ordnance devices in order to test loads, this means the
A. missile is ready for launch signals.
B. emergency backup power is sufficient.
*C. safety control switch (SCS) key is installed.
D. monthly weapon systems test is being conducted.
- (407) The LCC I-box provides an interface between the
*A. electrical surge arresters and electronic equipment.
B. electrical surge arresters and power filter.
C. power filter and electronic equipment.
D. power filter and circuit breaker panel.
- (407) What components of an ESA module limit the current entering the system during a surge condition?
A. carbon blocks
B. Gas-filled tubes
C. Spark gap assemblies
*D. Twenty-ohm resistors
- (408) What feature prevents the cables from being damaged when the shock-mounted floor moves?
A. Foam blocks
*B. Shock loops
C. Nylon straps
D. Cable attenuators
- (408) What LF I-box component device will only be used in the LF it’s designed for due to its site specific signal distribution?
A. Sorting plug
*B. Shorting plug
C. Site addressing plug
D. Keying variable plug
- (408) What device in a LF I-box protects against undesirable signals which may have been picked up on the HICS?
A. Metal oxide varistor
B. Feed-through capacitor
*C. Pulse suppressor assembly
D. Electrical surge arrester (ESA)
- (408) Which electrical filter assembly (EFA) located outside the ESA vault protects the security lines?
A. F-1344/GSW-13 (URD 10442)
*B. F-1343/GSW-13 (URD 10443)
C. F-1346/GSW-13 (URD 10439)
D. F-1345/GSW-13 (URD 10440)
- (408) EMI filtering for the [AISMP] secondary door is through
*A. 14 ESA modules
B. 8 ESA modules
C. 14 pi-filters
D. 8 pi-filters
- (409) Which weapon system control console (WSCC) component will provide an indicator for a fire alarm?
A. Master alarm reset (MAR)
B. Visual display unit (VDU)
*C. Auxiliary alarm panel (AAP)
D. Rapid message processor (RMP)