Chapter 1: Airplane General, Emergency Equipment, Doors, Windows Flashcards

1
Q

Recall the location of the POSITION, ANTI COLLISION, WING, WHEEL WELL, LANDING, RUNWAY TURNOFF and TAXI light switches.

A

LANDING, RUNWAY TURNOFF and TAXI light switches:
-Forward Overhead panel (lower edge, Captain side)

POSITION, ANTI-COLLISION, WING, and WHEEL WELL light switches:
-Forward Overhead panel (lower edge, F/O side)

Note: Due to heat buildup, the fixed landing and runway turnoff lights should not be on at the same time when the aircraft is on the ground and stopped.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Recall the location of the DOME WHITE switch.

A

Aft Overhead panel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Explain the function of the EMER EXIT LIGHTS switch.

A

OFF- Prevents emergency lights system operation if airplane electrical power fails or is turned off.

ARMED - (guarded position) All emergency lights illuminate automatically if:

  • Airplane electrical power fails or
  • AC Power is turned off.

ON- All emergency lights illuminate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Recall the emergency lights can be activated from the flight attendant panel regardless of flight deck switch position.

A

The emergency exit lights may be illuminated by a switch on the aft attendant’s panel. Lifting the guard and pushing the switch ON overrides the flight deck control and illuminates the emergency exit lights.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Recall the number and location of all emergency exits.

A

The airplane has two passenger entry doors, and two service doors (Passenger entry doors on the left, Cabin Service doors on the right).

In the flight deck, the number two windows, one on the left and one on the right, can be opened by the flight crew on the ground or in flight and can be used for emergency evacuation. Only the first officer’s number two window can be opened from outside the airplane.

Four overwing emergency exits are located in the passenger cabin.

There are 10 ways out and 9 ways in.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Locate the flight deck indications for open ENTRY, SERVICE, EQUIP, OVERWING and CARGO doors.

A

FWD ENTRY, FWD SERVICE, AFT ENTRY, AFT SERVICE, EQUIP, LEFT FWD OVERWING, RIGHT FWD OVERWING, LEFT AFT OVERWING, RIGHT AFT OVERWING, FWD CARGO, AFT CARGO
lights are located on the Forward Overhead Panel

Illumination of these door lights will trigger the DOORS annunciator and the both MASTER CAUTION lights.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Recall the recommended pavement width for a 180° turn.

A

Minimum width of pavement for 180° turn: 79.7 Feet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Recall the function of the overwing exit flight lock system. (During a normal takeoff and landing)

A

The flight lock system is designed to ensure that the flight locks will automatically lock during takeoff, in-flight, and landing and unlock on the ground to allow for opening of the over wing exit doors in emergency situations.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Recall the type and quantity of emergency equipment located on the
flight deck.

A

3 Crew Life Vests
1 Halon Fire Extinguisher
1 PBE
1 ELT
1 Crash Axe
3 Crew Oxygen masks
1 Pair Heat Resistant Gloves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Recall the location of the Passenger Oxygen system controls and
indicators.

A

Aft Overhead Panel (center).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Describe the function of the PASS OXYGEN switch.

A

NORMAL – (guarded position) passenger masks drop and passenger oxygen system activated automatically if cabin altitude climbs to 14,000 feet.

ON – activates system and drops masks if automatic function fails.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Recall the lights associated with an activated Passenger Oxygen system.

A

When the system is activated, the PASS OXY ON light illuminates and the OVERHEAD annunciator illuminates on the Master Caution System.

Note: Activating the system causes the masks to drop from the stowage compartments. The oxygen generators are activated when any mask in the unit is pulled down. Pulling one mask down causes all masks in that unit to come down and 100% oxygen flows to all masks. Oxygen flows for approximately 12 minutes and cannot be shut off.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly