Chap 4 Carbon Monoxide Flashcards

0
Q

Explosive range oF CO2

A

12.5 LEL

74 UEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Co properties

A
Colorless 
Odorless 
Tasteless 
Non-irritating 
Toxic gas
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Ignition temp of co2

A

1128 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Co is heavier or lighter than air

A

Slightly lighter than air (.968)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Co 2 is how more times attracted to hemoglobin than o2

A

210 x more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The IC at a co incident or emergency shall request the utility company to respond if

A
  1. Co level over 9 ppm
  2. Units on scene shut off gas meter
  3. An individual(s) is exhibiting symptoms of co poisoning
  4. The IC feels a response by utility company is required
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Co incident is

A

No occupants are symptomatic and meter readings of 9ppm or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Co emergencies

A

Occupants are symptomatic or meter readings greater than 9ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

SCBAs at co incidents

A

Worn on at all investigations
And used at all emergencies
Search premise with a ht equipt team of at Least two ff

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Operations at co incidents 9ppm or less ( no symptoms )

A
  1. Inform occupant that our meter has not detected elevated CO level
  2. Attempt to reset detector if does not reset or does not have reset recommend that occupant refer to manufactures instructions
  3. inform occupants that if detector activates again that they should call 911
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Co emergency actions over 9ppm but below 100 ppm

A

Over 9ppm not normal
Inform occupants that have potential dangerous co level
Recommend all ppl in affected area leave and start vent
If appliance shut it down
Once appliance shut down and vent and levels drop below 9ppm or less premise may be occupied
Attempt to,reset detector,
Inform the occupants of all actions taken and that utility company has been requested to respond
Inform occupant if detector goes off again call 911

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Co emergency of 100 ppm or greater

A
  1. Inform occupants that we have detected a potentially lethal level of co
  2. Begin evacuation of affected area
  3. If appliance problem shut it down
  4. If source mitigated and levels drop to 9ppm or less than reoccupy
  5. Attempt to,reset detector
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

10-38

A

Any type of co response

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

10-38 code 1

A

Detector activation : co investigation
Low battery
Unwarranted alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

10-38 code 2

A

Detector activation co 2 incident

Reading of 1ppm to 9ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

10-38 code 3

A

Detector activation

Co 2 emergency meter reading greater than 9ppm

16
Q

10-38 code 4

A

Co 2 emergency or incident no detector present in affected area or detector present but odd not activate