CHAP 12 water loss Flashcards

0
Q

If a kink occurs and cause water loss to reduce extinguishing capabilities who assures the fire is confined

A

The engine officer ensures fire is confined by closing door and /or all members are moved to save refuge area if necessary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Kink constitutes a water loss when severe enough to reduce the extinguishing capabilities of a hose line when discovered by any member

A

Urgent message via ht

Essential that IC units on fire floor and floors above be notified of water loss situation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Who is responsible for eliminating kinks at an operation

A

All members eng and ladder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If nozzle flow is insufficient and pressure on the discharge gauge reads normal or higher and reduced reading on flow meter this indicates

A

Kinks

Severely inadequate nozzle flow with normal pressure readings and severely reduced or no flow reading s on flow meter indicates severe or multiple kinks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Severely inadequate nozzle flow with readings remaining same on pressure gauges with engine speeds increasing automatically and high flow readings on flow meter means

A

Burst length

If rig has pro pressures governor reading will decrease on. Pressure gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Engine officer must initiate action to relief kinks or deal with burst length he should inform whom when these problems are corrected

A

IC and members on fire floor and floor above

Problem shall also be addressed by 2 nd due eng officer if on scene

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Two ways to deal with bursts length

A

If enough hose available remove burst length and reattach hose
Replace with another length of hose

Above situation only accomplished upon eng officers orders after the fire has been confined and or embers moved to safe refuge area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If short stretch and and adding to back of stretch water shut down is required

A

May be impractical if More than 4 lengths of hose are already deployed
If 6 lead lengths of 1 3/4 deployed only 2 1/2 can. E added

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If 1 3/4 hoseline is being added to short without water shut off than

A

Then bring lead length to nozzle
Remove tip from original nozzle
Attach lead length to female butt of shut off

NOTE engine officer will ensure shut off does not get accidentally shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If adding to short stretch with 2 1/2 hose without shutting water you

A

Bring length of 2 1/2 to nozzle
Remove tip from nozzle
Connect 1 1/2 to 2 1/2 increaser to shut off

Will be slight reduction in water flow
Compensate by increasing pressure
Attach increaser slightly pull back shut off handle to allow lugs on fitting to clear handle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The 1 1/2 to 2 1/2 increased shall be carried

A

In standpipe kit connected to extra 2 1/2 nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly