If a kink occurs and cause water loss to reduce extinguishing capabilities who assures the fire is confined
The engine officer ensures fire is confined by closing door and /or all members are moved to save refuge area if necessary
Kink constitutes a water loss when severe enough to reduce the extinguishing capabilities of a hose line when discovered by any member
Urgent message via ht
Essential that IC units on fire floor and floors above be notified of water loss situation
Who is responsible for eliminating kinks at an operation
All members eng and ladder
If nozzle flow is insufficient and pressure on the discharge gauge reads normal or higher and reduced reading on flow meter this indicates
Kinks
Severely inadequate nozzle flow with normal pressure readings and severely reduced or no flow reading s on flow meter indicates severe or multiple kinks
Severely inadequate nozzle flow with readings remaining same on pressure gauges with engine speeds increasing automatically and high flow readings on flow meter means
Burst length
If rig has pro pressures governor reading will decrease on. Pressure gauge
Engine officer must initiate action to relief kinks or deal with burst length he should inform whom when these problems are corrected
IC and members on fire floor and floor above
Problem shall also be addressed by 2 nd due eng officer if on scene
Two ways to deal with bursts length
If enough hose available remove burst length and reattach hose
Replace with another length of hose
Above situation only accomplished upon eng officers orders after the fire has been confined and or embers moved to safe refuge area
If short stretch and and adding to back of stretch water shut down is required
May be impractical if More than 4 lengths of hose are already deployed
If 6 lead lengths of 1 3/4 deployed only 2 1/2 can. E added
If 1 3/4 hoseline is being added to short without water shut off than
Then bring lead length to nozzle
Remove tip from original nozzle
Attach lead length to female butt of shut off
NOTE engine officer will ensure shut off does not get accidentally shut down
If adding to short stretch with 2 1/2 hose without shutting water you
Bring length of 2 1/2 to nozzle
Remove tip from nozzle
Connect 1 1/2 to 2 1/2 increaser to shut off
Will be slight reduction in water flow
Compensate by increasing pressure
Attach increaser slightly pull back shut off handle to allow lugs on fitting to clear handle
The 1 1/2 to 2 1/2 increased shall be carried
In standpipe kit connected to extra 2 1/2 nozzle