CH1 ANESTHESIA MACHINE AND EQUIPMENTS Flashcards
The control of mechanism of standard anesthesia ventilators is accomplished by
Compressed oxygen
full N20
psi:ml?
750 psi:1590 ml
How much should be consumed before n20 dec its psi?
three fourth of N20
DESFLURANE
vapor pressure?
665mmHg
what are the Test for low pressure part of the machine?
positive pressure test
this valve permit unidirectional flow of gases
CHECK VALVES
another term for pop off valve
adjustable pressure limiting valve
pressure sensor shut off valve
discontinue the flow of N2O
of the O2 below psi
FAIL SAFE VALVE
ratio 3:1
fixed mass of gas at constant temperature, the product of pressure and volume contact
BOYLE’s LAW
estimate the vol of gas remaining in a compressed gas cylinder by measuring the pressure within the cylinder
oxygen ?
psi:ml
2000 psi:625 ml
color of gases
o2 - green
n2o blue
air -yellow
BOBBIN not rotating ?
NO FLOW of O2
O2 and N2:
enters the anesthesia machine from a central supply source as (pressure)
N20?O2?
then pass true
first stage pressure regulator : ___psi
second stage of pressure: ___ psi
N20: 750 psi
O2: 2200 psi
then pass true
first stage pressure regulator : 45psi
second stage of pressure: 14 to 16 psi
NIOSH: N2O
highest trace of conc at the OR should be < _____ppm , In dental permit up to ____ppm
<25 -OR
<50 dental
identical saturated vapor pressure can be used interchangeably?
true or false
true
which volatile can be interchangeable
HI
HALOTHANE 243
ISOFLURANE 250
SEEN
SEVOFLURANE 160
ENFLURANE 178
occurs when gas flows through a region of severe constriction
TURBULENT FLOW
occurs when gas flows ws down parallel aided tube at a rate less than critical velocity
LAMINAR FLOW
Turbulent flow is directly proportional to
density of the gas
helium decrease the density
relationship between intra-alveolar pressure surface tensiin and radius of the alveoli is described by what law?
Laplace’s Law
states that the surface tension of the sphere is directly proportional to the radius of the sphere and pressure within the sphere
LAPLACE LAWS
flow of the oxygen is selected on a separate flowmeter to pass into the vaporizing chamber from which the anes vapor emerges at its saturated vapor pressure
measured flow vaporizer
total gas flow is split between a variable by pass and the vaporizer chamber containing the anesthetic agent
VARIABLE BY PSS VAPORIZER
in variable by pass vaporizer the ratio of these 2 flows is called the ?
SPLITTING RATIO
depends on the anes agent, the temperature, vapor conc and the saturated vapor pressure of the anesthetic
Factors that are involved in the production of C0 and formation of carboxyhemoglobin
specific volatile used DEIS=H high conc of volatile high temp low fresh gas flow dry soda lime
C0 production does not produce with what soda sorb?
Ca chlorode and CaOH
NIOSH Rregukation
highest conc of volatile anesthetics allowed in the OR in conjunction with N2O
0.5ppm
device on anesthesia machine that most reliably detects delivery of hypoxic gas mixture
O2 analyzer
most common complication of direct laryngoscopy and tracheal intubation ?
Dental trauma
most common complication while the et is in place
endobronchial intubation