Ch 3 Heat Treatments Of Milk Flashcards

1
Q

According to the PMO and 21 CFR 131.3, pasteurization is defined as:

A

A process that heats every particle of milk or milk product in properly designed and operated equipment, at or above the specified time and temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the requirements for Vat Batch Pasteurization (LTLT)?

A

145F for 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the pasteurization requirements for HTST?

A

161F for 15 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When is it required for the pasteurization temp to be increased by 5F?

A
  • fat content of the milk is 10% or higher
  • if total solids are 18% or higher
  • contains added sweeteners
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

_____ is the sub pasteurization heat treatment undefined by US Regulations

A

Thermization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the temperature range for thermization?

A

135-155F for 15 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If a cheese contains thermized milk, how must it be labeled in the US?

A

As containing raw milk

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Once milk has been pasteurized, is it more or less susceptible to microbial contamination?

A

More!!!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

During vat pasteurization, is the vat opened or closed?

A

Closed- if opened at any time, the 30 minute time starts over

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

______ is when milk is moved into a balance tank when there is a malfunction with continuous flow pasteurization (HTST)

A

Divert Flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What information is required to be recorded for pasteurization?

A
  • date and time
  • facility where pasteurization occurred
  • amount of milk
  • product to be made
  • operator
  • anything unusual that occurred
  • specific info regarding the type of pasteurizer used
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How long should pasteurization records be kept?

A

Must be kept 6 months

Good idea for cheese makers to keep as long as the product is still in the food chain. Is a CCP in a HACCP plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

_____ are tests used to confirm pasteurization on properly installed equipment

A

Alkaline Phosphatase testing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long after pasteurization should pasteurized milk be used for cheese making?

A

Immediately!

If not, must be cooled to <39F and used within 24 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

With LTLT pasteurization, what is the required temperature of the air above the surface of the milk and the lid of the vat?

A

150F

Must maintain throughout the 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the maximum heating/cooling time allowed for vat pasteurizer?

A

Cannot exceed 4 hours
* exception if it is also the cheese vat

17
Q

What test should be done daily to ensure that HTST pasteurizers are working correctly?

A

Cut in/cut Out temperatures

-verifies that the divert valves and thermometers are working correctly

18
Q

What records should be maintained in regards to pasteurization?

A
  • operating procedures
  • SSOP (sanitation standard operating procedures
  • staff training records
  • phosphatase tests
  • chart recordings used for either Vat or HTST
19
Q

What is soil?

A

Any material found in an incorrect location

Ex: fat deposits, lubricants, residue

20
Q

What are common examples of soil in a dairy plant?

A
  • Milk Sugar
  • Butterfat
  • proteins and denatured proteins
  • Mineral salts
  • hot milk films
  • milkstone
21
Q

What is the primary reason to clean pasteurizers?

A

To eliminate soil

22
Q

What is a CIP System?

A

Clean in Place

23
Q

In a CIP task, what temperature should the solution be and how long should the machine be cleaned?

A

30 minutes, typically 10F higher than the pasteurization temp used.

24
Q

In a production facility, what cleaning records should be kept and for how long?

A
  • every CIP system that has been cleaned/sanitized
  • date and time
  • temp of cleaning and sanitizing solution
  • length of time CIP equipment exposed to solution
  • signature/initial

Kept minimum of 90 days