Cargo Heat / Ventilation Panels - Rev 04 Flashcards
What does the CARGO HEAT HOT AIR amber FAULT light indicate?
(FCOM-DSC-21-40-30)
Duct overheat
What is the purpose of the CABIN FANS?
(FCOM-DSC-21-10-20)
To re-circulate cabin air to the mixing chamber and then back to the cabin
With BLOWER and EXTRACT push buttons in AUTO how does the system operate?
(FCOM-DSC-21-30-20, FCOM-DSC-21-30-60)
a. Ground – system is normally in the OPEN configuration
b. Flight – system is normally in the CLOSED configuration
c. Intermediate – Closed configuration except small internal flap in Extract Valve is open
With both BLOWER and EXTRACT push buttons in OVRD (smoke configuration) what are the positions of the INLET and EXTRACT valves?
(FCOM-DSC-21-30-20)
INLET valve CLOSED
EXTRACT valve OPEN
What is the status of the Blower and Extract fans with the Blower and Extract valves in OVRD?
(FCOM-DSC-21-30-20)
a. BLOWER fan OFF
b. EXTRACT fan ON
When is air conditioning introduced into the Avionics Compartment?
(FCOM-DSC-21-30-20)
a. Abnormal operation
b. SMOKE configuration
Is the skin heat exchanger ever bypassed in flight?
(FCOM-DSC-21-30-20)
Yes during SMOKE configuration
What does an amber FAULT light on the BLOWER push button indicate?
(FCOM-DSC-21-30-60)
a. SMOKE warning is activated
b. Computer power supply failure
c. Low Blower pressure
d. Duct overheat
What does an amber FAULT light on the EXTRACT pushbutton indicate?
(FCOM-DSC-21-30-60)
a. SMOKE Warning is activated
b. Computer power supply failure
c. Low Extract pressure
With 2 FAULT lights on the VENTILATION panel are there any other indications?
(FCOM-DSC-26-30-20)
Yes - The SMOKE light in the GEN 1 LINE push button