Air Conditioning Panel - Rev 04 Flashcards
The pneumatic system is monitored and controlled by…?
(FCOM-DSC-36-10-10)
2 Bleed Monitoring Computers (BMC)
If one BMC fails, can the other take over?
(FCOM-DSC-36-10-20)
a. Yes, they are interconnected. If BMC 1 fails:
b. APU and ENG 1 leak detection are not monitored
c. ECAM APU BLEED LEAK warning is lost
What pack flow rate is automatically selected when APU bleed air is in use or during single pack operation?
(FCOM-DSC-21-10-50)
HI
When should the PACK FLOW selector not be in the normal position?
(FCOM-PRO-NOR-SOP-06)
a. Select LO: A319/A320 less than 115 and A321 less than 140 customers
b. Select HI: Hot and humid conditions
c. During Smoke/Fumes removal, select HI as per the procedure
If the engine bleed air in-flight is too low what will occur?
(FCOM-DSC-21-20-30)
Engine speed is automatically increased to provide adequate bleed air pressure
What would cause an amber FAULT light to illuminate in the PACK 1 and/or Pack 2 push button?
(FCOM-DSC-21-10-50)
OOD
Overheat - Pack outlet
Overheat - Compressor outlet
Discontinuity - Switch position disagreement with pack flow control valve
Note: FAULT light will be illuminated when no bleed air is supplied.
What does the amber FAULT light in the APU BLEED push button indicate?
(FCOM-DSC-36-20)
Bleed leak
(APU bleed valve closes)
What causes the amber FAULT light on the ENG 1 BLEED and/or ENG 2 BLEED push button?
(FCOMDSC-36-20)
OOLDE
Overpressure - Downstream of the bleed valve
Overheat
Leak - Low pressure
Discontinuity - APU bleed valve open and engine bleed valve not closed or
Engine Start with bleed valve not closed
What are the two functions of the engine bleed valves?
(FCOM-DSC-36-10-20)
a. Pressure regulation
b. Shut off valves
At what cabin differential pressure does the RAM AIR valve open?
(FCOM-DSC-21-10-20)
1 PSI ΔP or less
What logic controls the X-Bleed valve when the X-BLEED switch is in AUTO?
(FCOM-DSC-36-10-40)
a. When APU bleed valve is OPEN, the X-Bleed valve is open
b. When APU bleed valve is CLOSED, the X-Bleed valve is closed
c. X-Bleed also CLOSES for wing, pylon, or APU duct leak (except during engine start)
What causes the Pack Flow Control valve to automatically close?
(FCOM-DSC-21-10-50)
UPEED
Upstream pressure below minimum
Pack overheat
Engine start sequence
Engine FIRE push button on the related side pressed
DITCHING push button is selected
What does an amber FAULT light in the HOT AIR push button indicate?
(FCOM-DSC-21-10-50)
Duct overheat - the Hot Air and Trim Air valves close automatically
How many Air Conditioning System Controllers are there?
(FCOM-DSC-21-10-10)
2 - Each Air Conditioning System Controller has 2 lanes -(Active/Standby)
Describe how the Air Conditioning System Controllers regulate temperature?
(FCOM-DSC-21-10-30)
a. Basic temperature regulation: Both packs produce the required outlet temperature determined by the lowest demanded zone temperature.
b. Optimized temperature regulation: Hot air is added to the individual zones by the trim air valves to maintain the desired zone temperatures.