CARGO FIRE PANEL Flashcards
1
Q
EXTINGUISHER TEST Lights
A
Illuminated (Green):
- Cargo Fire TEST switch is pushed and squib continuity is NORMAL (between panel and squibs)
- when TEST switch is pushed a low circuit signal is sent through the FWD and AFT squibs
2
Q
CARGO FIRE TEST Switch
A
PUSH: and hold
- tests circuits for both FWD and AFT cargo fire detector loops
- sends a test signal to the loops and verifies continuity of the squibs
- fire bell will sound
- MC lights DO NOT illuminate for the test
FAULT:
- if there is a squib fault the associated green light will not come on
TEST INDICATIONS:
- Bell
- FIRE WARN lts illuminate
- EXT FWD and AFT green lights come on
- FWD and AFT red switch lights come on
- amber DISCH light comes on
- [DETECTOR FAULT] amber light will NOT come on if its a good test
3
Q
DET SELECT Switches
A
- 3 positions: A - NORM - B
- 2 switches: FWD and AFT
NORM:
- loops A & B are active (dual loop design similar to OVHT/FIRE loops)
- to active smoke must be detected by A detector in loop A AND loop B (any detector in both loops - they do not have to be a pair) before alarm sounds
A / B:
- associated loop is active
- if any detector in the associated loop detects smoke an alarm will occur
Notes.
- if one detector fails in a loop it will automatically change to single loop system
- in single loop mode: alarm will set off if only ONE detector senses smoke
4
Q
CARGO FIRE ARM Switches & Lights
A
Switches.
-
PUSH -
- FWD ARMED: extinguisher ARMED for FWD cargo compartment (white ARMED light)
- AFT ARMED: extinguisher ARMED for AFT cargo compartment (white ARMED light)
- cannot see the word ARMED unless you push the switch
Warning Lights.
-
Illuminated (red): FWD / AFT
- at least ONE detector in EACH LOOP detects smoke (if in NORM)
- if down to a single loop - at least one detector on the remaining loop detects smoke (A or B)
- Master FIRE WARN lights and Bell sounds
- when you push the FWD / AFT switch you are arming the squib - then you push DISCH to fire the bottle
Indications of a Cargo Fire.
- Fire Bell
- both FIRE WARN lights
- FWD/AFT cargo fire warning light(s) illuminate
5
Q
DISCH Light and Switch
A
Light.
- Illuminated (amber): bottle has discharged
- NOT press to test (only tested by the Master Dim and Test Switch)
- may take up to 30 seconds to illuminate
- Halon 1301 pressurized with nitrogen
Switch.
- PUSH: if system is armed the bottle will discharge
- it is a HRD system (high rate discharge) to get the fire OUT
- only 1 bottle for both cargo bays
- provide fire suppression for 60 minutes (flt time) plus 15 min (fire suppression for missed appr or unloading etc)
- 2 nozzles in the ceiling of fwd cargo bay and 3 in the aft ceiling
6
Q
DETECTOR FAULT Light
A
-
Illuminated (Amber):
- one or more of the selected loops in EITHER cargo compartment has failed