Cap 4 Pengine Starting And Ignition Flashcards

1
Q

Starter operating light

A

Starter operating light should go off in 30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Magneto /spark pluges

A

One magneto provides current to half of all spark pluges and the other one the rest

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Switches in magneto

A

P switch and p lead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Capacitor

A

Capacitor absorbs excess current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Three methods of spark augmentation?

A

1) impulse coupling
2) low tension booster
3) high tension booster

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Low tension booster

A

Connect the dc power to Vibrator which fires some pulses to the secondary windings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

High tension booster

A

Battery connected with the vibrator directly to the distributor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Magneto check

A

Drop check > checking one magneto at a time

Dead cut check > turning of the magneto briefly to see if it turns off and then turn on back again before it stops

Drop check:
1st chek dead chek :At 1000-1200rpm for a drop in rpm
2nd ceck dead check: 2000 -2200rpm 75% ,monitor rpm ,should drop between 100-175 rpm indicating normal magneto .if the rpm drops greater than 400rpm there may be a faulty

Dead check: at 75% rpm turn off the switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly