Cabin Pressure Panel - Rev 01 Flashcards
Which valves will receive a close command when the DITCHING push button is depressed?
(FCOM-DSC-21-20-30)
ARPO
Avionics Inlet and Extract valves
Ram air inlet
Pack Flow Control valves
Outflow valve (only if in AUTO mode)
Will the DITCHING push button always close the outflow valve?
(FCOM-DSC-21-20-40)
Not if the outflow valve is under manual control
Can the pilot control the outflow valve?
(FCOM-DSC-21-20-30)
Yes, select MAN on the MODE SEL and use the MAN V/S CTL switch
How many controllers are in the pressurization system?
(FCOM-DSC-21-20-30)
2 - only one is used at a time and they swap roles after each landing
How do you manually switch controllers?
(FCOM-DSC-21-20-40)
Switch MODE SEL to MAN for 10 seconds, then back to AUTO
What does an amber FAULT light in the MODE SEL push button indicate?
(FCOM-DSC-21-20-40)
Both automatic pressure controllers are faulty
From what source does the pressurization system obtain landing elevation?
(FCOM-DSC-21-20-40)
FMGC database
When the mode selector is out of the AUTO position, how do you set a landing elevation?
(FCOM-DSC-21-20-40)
Manually by selecting landing elevation via the LDG ELEV dial
What protects the airframe from excessive cabin differential pressure?
(FCOM-DSC-21-20-20)
2 pressure relief valves (safety valves)
How many outflow valve motors are installed?
(FCOM-DSC-21-20-20)
3 - One for each automatic controller and one for manual control
Describe what occurs when cabin pressure altitude exceeds:
8800 ft
9550 ft
11300 ft
14000 ft
(FCOM-DSC-21-20-40, FCOM-DSC-21-20-50, FCOM-DSC-33-40-10, FCOM-DSC-35-30-10)
8,800 ft - CAB ALT flashes
9,550 ft - EXCESS CABIN ALT warning
11,300 ft - All cabin signs illuminate
14,000 ft - All passenger masks deploy