Book 29 Water Utilities Flashcards

1
Q

Book 29 Water Utilities

Supply systems are gravity or pump or a combination of both.

Gravity systems use a source of water (such as lakes and reservoirs) that is at a higher elevation than a municipality.

pumps are used to supply water at the proper pressure into a distribution system.

The City of Los Angeles uses a combination system to supply an average of 600 million gallons of water per day to 4 million people.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Book 29 Water Utilities

TRUNK LINES

Trunk lines carry water from a primary source (reservoirs, pumps, etc.) to mains within a distribution system.

Trunk lines can vary from ___ inches to ___ feet in size,

Constructed from iron or concrete.

A

36

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Book 29 Water Utilities

MAINS

Mains normally run beneath a street and parallel to a curb, can vary from ___ to ___ inches in size,

Constructed from iron pipe.

A

2 to 72

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Book 29 Water Utilities

SERVICE AND CUSTOMER LINES

Service lines run between a main and a water meter, can vary from ___ inch to ___ inches, and are constructed from iron, copper, or galvanized pipe.

Customer lines run between a water meter and a structure, can vary from ___ inch to ___ inches, and are constructed from iron, copper, galvanized, or plastic pipe.

A

1⁄2 to 12”

1⁄2 to 12”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Book 29 Water Utilities

Meter Box

The centerpiece or lid normally identifies the type of utility with the word(s) “WATER,” “DWP,” “L.A. Water,” “LA DWP WATER,” or “CITY WATER METER,” and are often marked with blue paint.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Book 29 Water Utilities

Non-Indicating Valves

These valves do not indicate an open or closed position and are characterized by ball or cone valves and gate valves.

A ball or cone valve has a rectangular valve-nut attachment on the top of the valve. When the valve is closed, the valve-nut is perpendicular to the valve.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Book 29 Water Utilities

Water meters are normally directly adjacent to shut-off valves and vary in size from ___ to ___ inches

A

1⁄2 to 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Book 29 Water Utilities

Compound meters (Low and High flow) are 4 inches or larger and are normally found directly adjacent to shut-off
valves.
A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Book 29 Water Utilities

Pressure Reducing Valves are normally used in domestic services to reduce high water pressures to an acceptable level inside a structure (i.e., dwellings commonly use ___ to ___ psi).

A

40 to 80

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Book 29 Water Utilities

Most detector check valves will use a small water meter in parallel with the check valve(s) to detect leaks and the unauthorized use of water.

Detector check valves can vary in size from 2 to 10-inches.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Book 29 Water Utilities

In warm climates, water meters can be placed just below grade level, and pressure reducing valves, shut-off valves, and detector check valves can be located above or below grade level

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Book 29 Water Utilities

SINGLE FAMILY DWELLINGS

1⁄2 to 2 inch single water meter

Water service for a domestic sprinkler system will normally be a 2 inch detector check valve that is located in a separate vault.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Book 29 Water Utilities

HOTELS

Domestic water and fire protection services are provided by a combination water service that provides domestic water with a 4 to 6 inch water meter and water for fire protection with a 4 to 8 inch detector check valve.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Book 29 Water Utilities

APARTMENTS

1 to 3 inch customer lines and a single 1 to 3 inch water meter with a shut-off valve on one or both sides of a meter.

Water service for fire protection will vary between 2 to 4 inches.

If a structure has Dorothy Mae Sprinklers, a separate 2 inch fire service vault is used.

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Book 29 Water Utilities

COMMERCIALS

A commercial occupancy with multiple occupancies (such as mini-malls), can be serviced with water for a domestic water service by a single water meter for an entire building or, by multiple, 1 to 2 inch water meters in separate vaults, which can supply each individual occupancy (referred to as a battery).

A

reference

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Book 29 Water Utilities

HIGH RISE

4 to 10 inch water meter for domestic water and 4 to 12 inch detector check valves for fire protection in the same vault.

A

reference

17
Q

Book 29 Water Utilities

Wet Standpipe. Designed for occupant use and consists of 100’ of 11⁄2” unlined singled jacketed hose with a 1⁄2” straight tip with no shut-off.

A

reference

18
Q

Book 29 Water Utilities

When closing a ball, cone, or gate valves that are 3 inches or larger, it may be necessary to exercise a valve to completely eliminate the flow of water as valves can become encrusted with rust and scale.

A

reference

19
Q

Book 29 Water Utilities

OS&Y valves are turned clockwise (so the stem is not visible) to stop the flow of water.

A

reference

20
Q

Book 29 Water Utilities

(fire hydrant gate valves may require __ to __ full turns to complete a shutdown).

A

18 to 26

21
Q

Book 29 Water Utilities

Although approximately ___% of all fire hydrant gate valves close in a clockwise direction, a member must recognize those instances when a counterclockwise rotation is necessary to close the valve.

A

98

22
Q

Book 29 Water Utilities

Leaks from commercial toilets can be eliminated by removing a cap over the relief valve and using a slot-head
screwdriver to turn the relief valve screw outward. This will let the valve seat and stop the flow of water to the toilet.

A

reference

23
Q

Book 29 Water Utilities

Urinals. Leaks from commercial urinals can be eliminated by removing a cap over the relief valve and using a slot-head screwdriver to turn the relief valve screw outward.

A

reference

24
Q

Book 29 Water Utilities

Sprinklers

Automatic Wet Pipe System
– Filled with water at all times

Automatic Dry Pipe System
– Filled with compressed air, heat activated

Non Automatic System
– Dry and Fire Dept. Pumps to system

Deluge System
– Open or closed heads, water is supplied by heat activated valve

A

reference

25
Q

Book 29 Water Utilities

A commercial occupancy with multiple occupancies (such as mini-malls), can be serviced with water for a domestic water service by a single water meter for an entire building or, by multiple, 1 to 2 inch water meters in separate vaults, which can supply each individual occupancy (referred to as a ______).

A

battery