Book 2: Unit 2 - Review: Flashcards
A water closet flush tank operates by means of two valves, one is the float-controlled valve (ball cock or float valve) that:
Select one:
A. Opens to flush the bowl
B. Opens to drain the tank
C. Opens to fill the tank
D. Closes to drain the tank
E. Closes to fill the bowl
C. Opens to fill the tank
An air gap is a physical separation between the free flowing discharge end of a potable water pipe and an open or non-pressure receiving vessel such as a:
Select one:
A. Sink or a bathtub
B. Process vessel
C. Storage tank
D. Mixing vat
E. Boiler
A. Sink or a bathtub
Wastes from plumbing fixtures, such as sinks, are discharged through the fixture outlet pipe and P-trap then passes into a:
Select one:
A. Vertical branch
B. Horizontal Line
C. Horizontal stack
D. Horizontal branch
E. Vertical stack
D. Horizontal branch
Water may leak from the flush valve of a water closet flush tank for the following reasons except:
Select one:
A. The flush seat might be corroded or worn
B. The ball could be defective
C. The lift chain could be properly adjusted
D. There might be dirt on the ball or the seat
E. The flush ball might not be seating properly
C. The lift chain could be properly adjusted
All horizontal piping should have an adequate slope and size to maintain a minimum flow velocity of _____ so that the solids are always kept in suspension, thereby preventing pipe blockage.
Select one:
A. 0.3 m/s (1 ft/sec)
B. 0.1 m/s (0.3 ft/sec)
C. 0.5 m/s (1.6 ft/sec)
D. 0.6 m/s (2 ft/sec)
E. 0.8 m/s (2.6 ft/sec)
D. 0.6 m/s (2 ft/sec)
The material used for indoor sanitary drainage piping in single family dwellings is:
Select one:
A. PVC plastic
B. Galvanized steel
C. Cast iron
D. Copper
E. ABS plastic
E. ABS plastic
Water hammer noise is a pounding or banging of pipes and shuddering of fixtures, caused by a shock wave that results when the water flow in a pipe is:
Select one:
A. Suddenly started
B. Slowly stopped
C. Suddenly stopped
D. Slowly started
E. Suddenly heated
C. Suddenly stopped
The pressure in the building plumbing system should not drop below _____ at any location.
Select one:
A. 175 kPa (25 psi)
B. 150 kPa (22 psi)
C. 200 kPa (29 psi)
D. 300 kPa (44 psi)
E. 250 kPa (36 psi)
A. 175 kPa (25 psi)
Fusible plugs are made of materials that melt at a temperature of:
Select one:
A. 90°C (194°F)
B. 99°C (210°F)
C. 125°C (260°F)
D. 225°C (440°F)
E. 150°C (300°F)
B. 99°C (210°F)
One of the methods employed to prevent backflow and control the cross connections is the:
Select one:
A. Atmospheric valve breaker
B. Temperature vacuum breaker
C. Air gap
D. Reduced temperature principal device
E. Double check breaker
C. Air gap
The standard or common trap has _____ of maintaining the seal.
Select one:
A. 16 mm (5/8 in)
B. 38 mm (1-1/2 in)
C. 75 mm (2-15/16 in)
D. 10 cm (4 in)
E. 5 cm (2 in)
B. 38 mm (1-1/2 in)
One of the methods employed to prevent backflow and control the cross connections is the:
Select one:
A. Atmospheric vacuum breaker
B. Temperature vacuum breaker
C. Double check breaker
D. Reduced temperature principal device
E. Air globe
A. Atmospheric vacuum breaker
One of the methods employed to prevent backflow and control the cross connections is the:
Select one:
A. Double check breaker
B. Temperature vacuum breaker
C. Atmospheric valve breaker
D. Reduced pressure principal device
E. Air globe
D. Reduced pressure principal device
Soil and waste material are moved through the drainage piping with the help of:
Select one:
A. Water
B. Steam
C. Oil
D. Grease
E. Air
A. Water
The deep trap has _____ of maintaining the seal.
Select one:
A. 10 cm (4 in)
B. 5 cm (2 in)
C. 16 mm (5/8 in)
D. 75 mm (2-15/16 in)
E. 38 mm (1-1/2 in)
A. 10 cm (4 in)