Biomechanics Flashcards
Palierne
2 locking plate constructs
VCOT 2019
Omission of 3rd innermost locking screw
~led to a 20% reduction in stiffness
~increased relative displacement of 40%
Beever
PO complications associated with ESF
VCOT 2018
Complications associated with
~Transarticular frames
~Age
Wagoner
Fiberglass & Thermoplast
VCOT 2018
FG > TP cranially
Lateral splints 64% reduction in frontal plane motion with FG
Macedo
2.5 mm Locking nail
VCOT 2017
Nail compared to 2.4 mm bone plate
1/2 torsional strength
1/3 stiffness
Slippage of the locking mechanism was probably the cause of the early failure
Ficklin
Biomechanics of PMMA & Abs
VCOT 2016
Compression changed by Vancomycin
4-point bending
~Sliver weaker than control
~Vancomycin lower than standard
Cephazolin least affect
Marturello
I-Loc Feline Fx
VetSurg 2021
Time to clinical union 7.2 weeks
Mean fill of 50%
I-Loc 3 is likely appropriate for all feline humeri
I-Loc 4 is well sized for feline femora
Muro
Stiffness Type II Ex Fix vs. LCP
VetSurg 2021
ESF stiffer than LCP
~ML Bending
~Axial Compression
Equal in CC Bending
Type II ESF stiffer
ML bending than in CC bending
LCP stiffer
CC bending than in ML bending