AUDIO|Maintenance|Cargo Heat|Cargo Smoke|Ventilation Flashcards

1
Q

What is the AUDIO SWITCHING PANEL used for?

A

Allows for switching to ACP 3 if ACP 1 or 2 fails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are we checking on the Maintenance Panel during the preliminary flight deck prep flow?

A

Checking that all lights are extinguished. If not contact maintenance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the CARGO HEAT HOT AIR amber FAULT light indicate?

A

Duct overheat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many fire extinguishers are provided for the cargo compartments?

A

a. 1 bottle, which can be discharged to either compartment
b. 2 bottles, which can be discharged to either compartment. 205 min discharge requirement for ETOPS
(ETOPS certified aircraft)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does the red SMOKE light in the FWD or AFT pushbutton indicate?

A

a. Both channels detect smoke, or
b. One channel faulty and the other detects smoke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many smoke detectors are there?

A

a. 2 forward cargo
b. 4 aft cargo

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

With a CARGO SMOKE warning what happens to the Isolation Valve and Extract Fan?

A

a. Isolation Valve closes
b. Extract Fan stops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the purpose of the CABIN FANS?

A

To re-circulate cabin air to the mixing chamber and then back to the cabin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

With BLOWER and EXTRACT pushbuttons in AUTO how does the system operate?

A

a. Ground – system is normally in the OPEN configuration
b. Flight – system is normally in the CLOSED configuration
c. Intermediate – Closed configuration except small internal flap in Extract Valve is open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

With both BLOWER and EXTRACT pushbuttons in OVRD (smoke configuration) what are the positions of the INLET
and EXTRACT valves?

A

a. INLET valve CLOSED
b. EXTRACT valve OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the status of the Blower and Extract fans with the Blower and Extract valves in OVRD?

A

a. BLOWER fan OFF
b. EXTRACT fan ON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When is air conditioning introduced into the avionics compartment?

A

a. Abnormal operation
b. SMOKE configuration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Is the skin heat exchanger ever bypassed in flight?

A

Yes during SMOKE configuration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does an amber FAULT light on the BLOWER pushbutton indicate?

A

a. SMOKE warning is activated
b. Computer power supply failure
c. Low blower pressure
d. Duct overheat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does an amber FAULT light on the EXTRACT pushbutton indicate?

A

a. SMOKE Warning is activated
b. Computer power supply failure
c. Low Extract pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

With 2 FAULT lights on the VENTILATION panel are there any other indications?

A

Yes – The SMOKE light in the GEN 1 LINE pushbutton