APU Limitations Flashcards
How many?
One, Garrett GTCP-36-150RJ
Indications and colors for APU EGT?
APU EGT 'C Limit: 743 Red: > 743 Amber: 713 to 742 Green: 0 to 712 Starting: 974
Red: Maximum and minimum limitations
Amber: Caution Range
Green: Normal Operating Range
Indications and colors for APU RPM?
APU RPM % Limit: 107 Red: > 107 Amber: 101 to 106 Green: 0 to 100
Red: Maximum and minimum limitations
Amber: Caution Range
Green: Normal Operating Range
Minimum ambient temperature for starting a cold soaked APU on the ground?
-40’C
APU Start on Battery
Start, Max Time On, Followed By
Start 1:
Max time on 30 seconds
Followed by 2 min. off
Start 2:
Max time on 30 seconds
Followed by 20 min. off
Start 3:
Max time on 30 seconds
Followed by 2 min. off
Start 4:
Max time on 30 seconds
Followed by 40 min. off
APU Start Using
DC Power
(Start, Max Time On, Followed By)
Start 1:
Max time on 15 seconds
Followed by 2 min. off
Start 2:
Max time on 15 seconds
Followed by 20 min. off
Start 3:
Max time on 15 seconds
Followed by 2 min. off
Start 4:
Max time on 15 seconds
Followed by 40 min. off