What is the regulated Power Output of the APU Generator?
28 v DC 400 amp
From where does the APU draw its fuel?
LH Collector Tank
What does the Amber WARN Legend on the APU Panel indicate?
The GEN function is not online and so batteries may be discharging.
What are the indications the the APU Generator is on line?
Green ON light on the GEN switch. ELEC SYS Load on APU gen.
What would prevent a serviceable APU generator from coming on line?
EXT PWR switch ON, Engine bleed switch to ON.
What will cause a serviceable APU to shut down?
Use of the FIRE Test Button on the Fire protection panel. WOW sensors on take-off
What should happen in the event of an APU Fire?
APU Fire Warning - Automatic Shutdown, within 7 seconds, Automatica Fire Suppression.
What are the Starter Cranking Limits for the APU?
60 secs on, 5 mins off, 60 on Maint’ action required
The APU gen cannot operate at the same time as an engine DC gen, true/false?
False
When is APU Running not permitted?
Starting Checks, Start No. 1 is APU starting, on EXT PWR
What is the APU Post-automatic Shut-down Procedure?
Check APU Control panel, confirm shut down, BLEED, GEN and PWR selected off, Do not restart
What will generate an APU Automatic Shut-down?
APU fault or fire, take-off, overspeed or under-speed