Anaesthesia II Flashcards

1
Q

Purpose of anesthesia machines. Pick the false answer
A. Administer appropriate flow of oxygen
B. Administer appropriate concentration of inhalants
C. Administer constant rate infusions
D. Elimination of exhaled CO2

A

C. Administer constant rate infusions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
Mixing part of the anesthesia machine. Pick the false answer
A. Gas source
B. Flowmeter
C. Vaporizer
D. One-way valves
A

D. One-way valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
Breathing circuit of the anesthesia machine. Pick the false answer
A. „Y”-piece
B. Reservoir bag
C. Oxygen bypass button 
D. CO2 absorbent canister
A

C. Oxygen bypass button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
Mixing system
A. 1 
B. 1+2 
C. 3 
D. 7
A

B. 1+2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
High-pressure part of the mixing system
A. 1 
B. 2 
C. 1+2 
D. 5
A

A. 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
Low-pressure part of the mixing system
A. 1 
B. 2 
C. 1+3 
D. 3
A

B. 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
Breathing circuit
A. 2+3 
B. 3
C. 12+14 
D. 9
A

B. 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
Gas source
A. 7 
B. 4 
C. 6 
D. 13
A

B. 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
Pressure regulator
A. 5 
B. 6 
C. 7 
D. 8
A

A. 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
Oxygen bypass
A. 5 
B. 6 
C. 7 
D. 15
A

B. 6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
Flowmeter
A. 5 
B. 6 
C. 7 
D. 8
A

C. 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
Vaporizer
A. 5 
B. 6 
C. 7 
D. 8
A

D. 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
Reservoir bag
A. 8 
B. 9 
C. 10 
D. 11
A

B. 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
Absorbent canister
A. 6 
B. 8 
C. 10 
D. 15
A

C. 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
Inspiratory one-way valve
A. 5 
B. 15 
C. 12 
D. 14
A

C. 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
Expiratory one-way valve
A. 5 
B. 15 
C. 12 
D. 14
A

D. 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q
Pop-off (Adjustable Pressure Limiting) valve
A. 5
B. 15
C. 6
D. 12+14
A

B. 15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q
Constant secondary pressure is provided by...
A. 5 
B. 6 
C. 7 
D. 15
A

A. 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q
Flow rate of source gas is set by...
A. 5 
B. 7 
C. 8 
D. 15
A

B. 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q
Anesthetic concentration is set by...
A. 5 
B. 7 
C. 8 
D. 10
A

C. 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q
Balances volume changes during inspiration and expiration
A. 7 
B. 12 
C. 14 
D. 9
A

D. 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q
Absorbs exhaled CO2
A. 10 
B. 15 
C. 8 
D. 13
A

A. 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q
Maintains unidirectional flow in inspiratory ribbed tube
A. 6 
B. 12 
C. 14 
D. 15
A

B. 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q
Maintains unidirectional flow in expiratory ribbed tube
A. 6 
B. 12 
C. 14 
D. 15
A

C. 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q
Prevents excessive pressure in the circuit and lungs
A. 5 
B. 6 
C. 9 
D. 15
A

D. 15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q
Dead space in the system
A. 4 
B. 8 
C. 9 
D. 13
A

D. 13

27
Q

Oxygen-bypass. Pick the false answer
A. Emergency option
B. Concentration of inhalational anesthetic in the circuit can be quickly reduced
C. Pure O2 can directly enter the circuit
D. The bypass rate is controlled by the flowmeter

A

D. The bypass rate is controlled by the flowmeter

28
Q
Optimal breathing tubes are... Pick the false answer
A. Ribbed 
B. Short 
C. Wide 
D. Blue
A

D. Blue

29
Q
Optimal size of the reservoir bag is...
A. The respiratory volume
B. 2 times the respiratory volume 
C. 5 times the respiratory volume 
D. 10 time the respiratory volume
A

C. 5 times the respiratory volume

30
Q
The absorbent canister is part of the... Pick the false answer
A. Open system
B. Semi-open system
C. Semi-open and semi-closed systems 
D. Semi-closed and closed systems
A

A. Open system

31
Q

CO2 absorption. Pick the false answer
A. The absorbent canister contains absorbing soda
B. The absorbing soda granules have a rough surface
C. The absorbing soda granules consist of Mg-hydroxide D. Exhaustion of the soda is indicated by discoloration

A

C. The absorbing soda granules consist of Mg-hydroxide

32
Q

The pop-off valve (Adjustable Pressure Limiting valve)… Pick the false answer
A. Prevents excessive pressure in the circuit and lungs
B. Is open during spontaneous breathing
C. Is set to 20 cmH2O during manual or mechanical ventilation
D. Is set to 40 cmH2O in case of compromised lung

A

D. Is set to 40 cmH2O in case of compromised lung

33
Q

Advantages of semi-open narcosis systems. Pick the false answer
A. Low resistance
B. Small mechanical dead space
C. Anesthetic concentration can be quickly modified
D. Large anesthetic consumption

A

D. Large anesthetic consumption

34
Q

Advantages of closed narcosis systems. Pick the false answer
A. Low source gas consumption
B. Low inhalational anesthetic consumption
C. Cheap
D. Easily controllable depth of anesthesia

A

D. Easily controllable depth of anesthesia

35
Q
Narcosis systems. Pick the false answer
A. Open circuit
B. Semi-open system 
C. Semi-closed circuit
D. Closed circuit
A

A. Open circuit

36
Q

Indications for mechanical ventilation. Pick the false answer
A. Open thorax
B. Neuromuscular blockade
C. Hypoventilation caused by severe hypothermia
D. Decreased etCO2 level

A

D. Decreased etCO2 level

37
Q

IPPV (Intermittent Positive Pressure Ventilation). Pick the false answer
A. Commonly used type of mechanical ventilation
B. Airway pressure is higher than atmospheric pressure during inspiration
C. Airway pressure falls to atmospheric pressure during passive expiration
D. Can not be used in large dogs

A

D. Can not be used in large dogs

38
Q
Physiological dead space means...
A. Anatomical dead space
B. Anatomical + alveolar dead space 
C. Alveolar dead space
D. Anatomical + apparatus dead space
A

B. Anatomical + alveolar dead space

39
Q

Inspiration. Pick the false answer
A. Spontaneous inspiration is caused by decreasing intrapleural pressure
B. IPPV inspiration is caused by increasing intrapleural pressure
C. Expiration is spontaneous in both cases
D. IPPV expiration is caused by negative intrapleural pressure

A

D. IPPV expiration is caused by negative intrapleural pressure

40
Q

CNS effects of IPPV. Pick the false answer
A. Controlled hyperventilation reduces CO2 levels in the blood
B. Reduced CO2 level causes arterial vasoconstriction
C. Arterial vasoconstriction decreases intracranial pressure
D. Severely decreased intracranial pressure supports cerebral oxygenation

A

D. Severely decreased intracranial pressure supports cerebral oxygenation

41
Q

Volume-controlled time-cycled mechanical ventilation. Pick the false answer
A. Common in veterinary anesthesia
B. Constant flow during inspiration
C. Inspiratory pressure decreases during inspiration to maintain a constant flow
D. Inspiratory phase ends after the preset inspiratory time

A

C. Inspiratory pressure decreases during inspiration to maintain a constant flow

42
Q
Triggering types (initiation of inspiratory phase). Pick the false answer
A. Time
B. Pressure
C. Flow
D. Concentration
A

D. Concentration

43
Q

Parameters of ventilation. Pick the false answer
A. Tidal volume: 10–15 ml/bwkg
B. Respiratoryrate:80–100/min
C. Inhalation/exhalationtimeratio:1:2–1:3
D. Target values: 35–45 mmHg etCO2 and 100% SpO2

A

B. Respiratoryrate:80–100/min

44
Q
Blood pressure measuring methods. Pick the false answer
A. Femoral pulse quality evaluation 
B. Invasive direct
C. Noninvasive doppler
D. Noninvasive oscillometric
A

A. Femoral pulse quality evaluation

45
Q

Blood pressure measurement at right atrial height
A. Measured lower, the value will be higher
B. Measured higher, the value will be lower
C. 10 cm height difference results in a deviation of 7.36 mmHg
D. 10 cm height difference results in a deviation of 73.6 mmHg

A

C. 10 cm height difference results in a deviation of 7.36 mmHg

46
Q

Cuff size for BP measuring. Pick the false answer
A. Patients of different sizes require different sizes of cuffs
B. Optimal cuff’s with is 40% of leg’s circumference
C. Optimal cuff’s with is 140% of leg’s circumference
D. Wider cuff produces lower BP value and vica versa

A

C. Optimal cuff’s with is 140% of leg’s circumference

47
Q

The MAP (mean arterial pressure) is…
A. Average of the systolic and diastolic values
B. Rarely lower than diastolic pressure
C. Closer to diastolic pressure than to systolic pressure D. Closer to systolic pressure than to diastolic pressure

A

C. Closer to diastolic pressure than to systolic pressure

48
Q
Urine production during general anesthesia
A. 0.1-0.2 ml/bwkg/h 
B. 1-2 ml/bwkg/h
C. 10-20 ml/bwkg/h 
D. 100-200 ml/bwkg/h
A

B. 1-2 ml/bwkg/h

49
Q
Pulse oximetry. Pick the false answer
A. Noninvasive method
B. Continuous measurement
C. Measurement of O2-saturation of Hb (%) 
D. The target value is 89%
A

D. The target value is 89%

50
Q

Pulse oximetry. Pick the false answer
A. Physiological range of oxygen saturation: 35–45 mmHg
B. Sensor can be placed on tongue, ear etc.
C. In case of transmission type sensors one side emits, while the other detect slight
D. Absorption depends on oxyHb/desoxyHb ratio

A

A. Physiological range of oxygen saturation: 35–45 mmHg

51
Q

Most pulse oximeters display. Pick the false answer.
A. Signal strength
B. Saturation and pulse frequency
C. Plethysmogram
D. Ratio of abnormal/normal hemoglobin types

A

D. Ratio of abnormal/normal hemoglobin types

52
Q
Correlation between paO2 and SpO2
A. Positive correlation
B. Negative correlation
C. Can be shown with sigmoid curve
D. Small changes in SpO2 are caused by large changes of paO2 (in the physiological range)
A

C. Can be shown with sigmoid curve

53
Q

Causes of malfunction of pulse oximeter. Pick the false answer
A. Strong pulse
B. Total light absorption
C. Improper contact
D. Interference with electrosurgical devices

A

A. Strong pulse

54
Q

Capnometry. Pick the false answer
A. Physiological range of etCO2: 35–45 mmHg
B. Capnogram may be divided into 4phases
C. In case of hypoventilation etCO2 decreases
D. Exhausted CO2 absorbent soda lime increases inhaled CO2 level

A

C. In case of hypoventilation etCO2 decreases

55
Q

Correlation of paCO2 and etCO2. Pick the false answer
A. Positive correlation
B. Negativecorrelation
C. PaCO2>etCO2
D. The difference in small animals is 2-5 mmHg

A

A. Positive correlation

56
Q
Capnograph types
A. Side-flow and main-flow measuring 
B. Left-sided and right-sided measuring 
C. Low-flow and high-flow measuring 
D. Mono-flow and multi-flow measuring
A

A. Side-flow and main-flow measuring

57
Q

Capnogram phases
A. Phase I (inhalation), Phase II (exhalation begins), Phase III (exhalation ends), Phase IV (inhalation begins)

B. PhaseI(exhalationbegins),PhaseII(exhalationends),PhaseIII(inhalationbegins),PhaseIV (inhalation)

C.PhaseI(exhalationends),PhaseII(inhalationbegins),PhaseIII(inhalation),PhaseIV(exhalation begins)

D. Phase I (inhalation begins), Phase II (inhalation), Phase III (exhalation begins), Phase IV (exhalation ends)

A

A. Phase I (inhalation), Phase II (exhalation begins), Phase III (exhalation ends), Phase IV (inhalation begins)

58
Q

Causes of decreasing etCO2. Pick the false answer
A. Acute respiratory distress (e.g. hyperventilation)
B. Acute respiratory distress(e.g.hypoventilation)
C. Acute circulatory distress(e.g.decreased heart minute volume)
D. Acute metabolic distress

A

B. Acute respiratory distress(e.g.hypoventilation)

59
Q

Causes of zero etCO2 on the capnograph’s display. Pick the false answer
A. Capnograph performs calibration (calibration message is displayed) B. Cardiac arrest, respiratory arrest
C. Tube malposition, disconnection
D. Capnoperitoneum (endoscopy)

A

D. Capnoperitoneum (endoscopy)

60
Q

Causes of rebreathed CO2. Pick the false answer
A. High flow in semi-open non rebreathing system
B. Exhausted sodalime
C. Stucked one-way valves
D. Large dead space

A

A. High flow in semi-open non rebreathing system

61
Q
Core-temperature can be measured with... Pick the false answer
A. Pharingeal probes 
B. Esophageal probes
C. Rectal probes
D. Thermocamera
A

D. Thermocamera

62
Q
Warming hypothermic patient. Pick the false answer
A. Heating pads
B. Infrared lamps
C. Covers and heat mirrors 
D. Hot IV infusion
A

D. Hot IV infusion

63
Q
Close control of blood glucose level is needed in... Pick the false answer
A. Very small or young patients
B. Acute trauma and shock patients 
C. Cachectic or weak patients
D. Diabetic or insulinoma patients
A

B. Acute trauma and shock patients

64
Q
Monitoring of anesthetized patients involves assessment of... Pick the false answer
A. The stage of narcosis 
B. Pain markers
C. Patient’s parameters 
D. Owner’s consent
A

D. Owner’s consent