Alain's Test - Green Clip Flashcards
A carpenter weights 195 pounds. their tools weigh 150 lbs and the material weighs 290 lbs. The total weight that a job-built scaffold must support is:
a) 635 lbs
b) 1270 lbs
c) 1905 lbs
d) 2540 lbs
d) 2540 lbs
The proper procedure for insuring the accuracy of reference lines required for a floor tile application is to:
a) locate centre of floor from the short wall, snap line, then 3, 4, 5
b) snap diagonal lines from the corners fo the floor, then lay out lines with a straight edge
c) measure in from the centre of the door opening then lay out lines with a framing square
d) determine centre of floor from the long wall, snap line, then 3, 4, 5
d) determine centre of floor from the long wall, snap line, then 3, 4, 5
When performing “tilt-up” wall construction procedures, to counteract the shifting of the centre of gravity (created by large openings at one end of the it is of Utmost importance to:
a) add additional reinforcement at the stress points of the wall openings
b) provide randomly spaced lifting inserts for the tilt-up wall panel
c) attach tag-lines to the open end of the tilt-up wall panel
d) provide engineered spacing of the lifting inserts for the tilt-up wall panel
d) provide engineered spacing of the lifting inserts for the tilt-up wall panel
When framing floor openings that require double headers at each end, the LAST? member to be placed in the framing assembly is the:
a) inside header
b) tail joists
c) outside trimmer
d) outside header
c) outside trimmer
A man basket weighs 475 lbs, a carpenter weighs 210 lbs, tools weight 195 lbs. With a 10:1 ratio a cable must be able to support:
a) 2100 lbs
b) 4050 lbs
c) 6850 lbs
d) 8800 lbs
d) 8800 lbs
The proper procedure for laying out a door knob when a template is not provided is to:
a) line up the faceplate with the edge of the door and locate a pencil mark through the hole provided in the latch unit
b) set a combination square for 1/2 the door thickness, mark the edge, reset the combination square for the required backset, mark the face
c) use a pocket tape to mark both the edge and the face of the door
d) build a template out of 1/4 inch thick material and mark the required layout
b) set a combination square for 1/2 the door thickness, mark the edge, reset the combination square for the required backset, mark the face
The National Building Code states that the minimum snow load that must be considered for a building that measures 5 m wide (being constructed in Churchill, Manitoba) will be:
a) 1.3 kPa
b) 1.5 kPa
c) 1.56 kPa
d) 1.76 kPa
find answer in code book
In order to rectify a “binding” door hinge you would:
a) straighten the pin in a bench vise
b) place shims between the hinge leaf and the gain toward the butt side of the hinge
c) give it a blow with the hammer
d) place shims between the hinge leaf and the gain toward the knuckle side of the hinge
d) place shims between the hinge leaf and the gain toward the knuckle side of the hinge
Timber framework transverse to the length of a structure usually designed to carry lateral as well as vertical loads is commonly referred to as a:
a) bent
b) T-shore
c) abutment
d) inverted U-shore
a) bent
When stripping the formwork from the underside of a suspended concrete floor slab, the first operation is to:
a) loosen the screw-jackets
b) remove the U-heads
c) lower the stringers
d) release the wedges
a) loosen the screw-jackets
When performing a through boring operation on a piece of finished stock the correct procedure to follow is to:
a) bore a pilot hole first, then bore the through hole
b) bore from one side then the other
c) bore a clearance hole on both sides, then bore the through hole
d) bore a countersink hole on one side, then bore the through hole from the other side
b) bore from one side then the other
Specifications call for 12” x 12” acoustical ceiling tile to be applied to a ceiling that measures 14’ - 3” x 18’ - 5”
The size of the border tile will measure:
a) 6 1/4 “ x 7 1/4 “
b) 7 1/4 “ x 8 1/4 “
c) 7 1/2 “ x 8 1/2 “
d) 8 1/2 “ x 9 1/4 “
c) 7 1/2 “ x 8 1/2 “
When pouring concrete in a concrete stair form, deflection of the middle of the stair form can be stopped by:
a) adding diagonal reinforcement to the apron of the stair
b) installing bracing to the sides of the stair form
c) slowing down the rate of pour
d) adding an inverted stair horse to the centre of the stair form
d) adding an inverted stair horse to the centre of the stair form
In order to provide safe access to a work surface located 12’ - 0” vertically from the base of the structure, the minimum length of the ladder required will be:
a) 13’-0”
b) 14’-0”
c) 15’-0”
d) 16’-0”
d) 16’-0”
Specifications call for 1” x 2” nominal strapping to be applied 24” o/c horizontally to a wall that measures 8’-0” high and 32’-0” long.
The amount of strapping required will be:
a) 96 lin ft
b) 128 lin ft
c) 160 lin ft
d) 192 lin ft
c) 160 lin ft
The type of sheathing insulation that will provide the best R-value is:
a) fibre-glass rigid
b) polystyrene rigid
c) urethane rigid
d) polyurethane rigid
d) polyurethane rigid
When laying out the seat cut for a valley rafter on an unequal pitch roof, use:
a) L.P.F.R. of Hip or Valley & 12”, mark on 12”
b) Total Rise & Total Run, mark on total run
c) L.P.F.R. of Hip or Valley & unit rise, mark on unit rise
d) Total Rise & Total Run, mark on Total Rise
b) Total Rise & Total Run, mark on total run
In order to form an isolation joint between a column and a slab, the best material to use would be:
a) polyethylene
b) plywood
c) bituminous board
d) tar paper
c) bituminous board
The part of a wooden pile that prevents belling of the top of the pile while it is being driven is the:
a) pile shoe
b) pile ring
c) pile cap
d) pile casing
b) pile ring
A cabinet door which allows only half of the space to be accessed at one time is a:
a) flush door
b) sliding door
c) overlay door
d) lipped door
b) sliding door
The proper installation of vinyl siding calls for:
a) tight fitting end joints and large head nails driven home
b) gaps at end joints and large head nails not driven home
c) tight fitting end joints and adhesive and nails in alternate courses
d) gaps at end joints and large head nails driven home
b) gaps at end joints and large head nails not driven home
The National Building Code states that the projection of a handrail installation required width of a stairway shall be no more than:
a) 25 mm
b) 50 mm
c) 75 mm
d) 100 mm
find using code book
d) 100mm
The National Building Code states that the minimum length of landing exterior stairs is:
a) 600 mm
b) 900 mm
c) 1070 mm
d) 1100 mm
find using code book
b) 900 mm
The National Building Code states that non-bearing walls parallel to the floor joists should be supported by joists beneath the wall or on blocking between the joists.
Such blocking shall be not less than:
a) 19 mm x 39 mm lumber, spaced not more than 0.6 M apart
b) 38 mm x 89 mm lumber, spaced not more than 1.2 M apart
c) 38 mm x 184 mm lumber, spaced not more than 2.4 M apart
d) 38 mm x 235 mm lumber, spaced not more than 4.8 M apart
b) 38 mm x 89 mm lumber, spaced not more than 1.2 M apart