AIRCRAFT ELECTRICAL SYSTEM Flashcards

1
Q

What is a cause of generator brush arcing?

A

Low spring tension

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many cycles of ac voltage are produced in a six pole alternator of the
revolving field type for each revolution of the rotor?

A

Three

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The type of electric wire terminals used for most aircraft applications, in
addition to providing good current carry-ing capabilities, are designed
primarily___________.

A

to prevent circuit failure due to terminal disconnection.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The commutator of a generator__________ .

A

changes alternating current produced in the armature into direct current
as it is taken from the armature.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

An ammeter in a battery charging system is for the purpose
of indicating the

A

rate of current used to charge the battery.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which of the following is not one of the purposes of interpoles in a generator?

A

Reduce arcing at the brushes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the color and orientation of the position lights for navigation on civil
airplanes?

A

Left side - red, right side - green, rear aft - white

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does a rectifier do?

A

Changes alternating current into direct current.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When a diode is checked for an open circuit or a short circuit, it should be

A

disconnected from the circuit.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

For general electrical use in aircraft, the acceptable method of attaching a
terminal to a wire is by…

A

crimping.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the minimum bend radius for an electrical wire bundle?

A

Ten times the outside diameter of the bundle.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When approved, splices may be used to repair manufac-tured harnesses or
installed wiring. The maximum number of splices permitted between any
two connectors is______ .

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

AN/MS electrical connectors are specifically designed to meet…

A

military specifications.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The most common method of attaching a pin or socket to
an individual wire in an MS electrical connector is by

A

crimping and soldering.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The voltage output of an alternator may be regulated by controlling the____ .

A

resistance in the rotor windings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Grounding is electrically connecting a conductive object to the primary
structure. One purpose of grounding is to_________.

A

prevent development of radio frequency potentials.

17
Q

Aircraft fuse capacity is rated in..

A

Amperes.

18
Q

Circuits that must be operated only in an emergency or whose inadvertent
activation could endanger a system frequently employ…

A

guarded switches.

19
Q

What protection to wires and cables does conduit provide when used in
aircraft installations?

A

Mechanical.

20
Q

Electric circuits are protected from overheating by means of..

A

Fuses.