AIR_AIR CONDITIONING CONTROLS PANEL Flashcards
1
Q
AIR TEMP Indicator
A
- indicates temperature at the location selecte by the AIR TEMP source selector.
2
Q
AIR TEMP Source Selector
- 7 positions in 3 groupings -
SUPPLY DUCT: Cont Cab / Fwd / Aft
PASS CAB: Fwd / Aft
PACK: R / L
A
- SUPPLY DUCT: shows SUPPLY DUCT temps of Cont Cab - Fwd Cab - Aft Cab
-
PASS CAB:
- selects forward or aft pax cabin temps
- there are 2 pax cabin temp sensors in the RIGHT side of cabin
- does NOT show temp of CONT CAB (this sensor is in theceiling of the cockpit)
- PACK: selects left or right PACK temps
3
Q
TRIM AIR Switch
A
OFF:
- trim air PRSOV signaled to CLOSE
- all 3 zone trim air systems are mechanically and electrically disabled
-
causes trim air system to operate in UNBALANCED AVG mode (ie 2 zone plane)
- left and right controllers will control packs independently
- Left Pack = controlled via the CONT CAB selector for temp
- Right Pack = average the demands of FWD and AFT zones
ON:
- trim air PRSOV signaled to OPEN
- causes BOTH packs to be controlled by the zone with the LOWEST temp setting (BALANCED MODE)
- enables the zone trim channels in the pack/zone temp controllers
4
Q
ZONE TEMP Lights
If this light comes on, what does that mean? (1sp)
A
[1sp: the respective temperature for that particular zone is too high and the respective trim air valve will close.]
Illuminated (Amber):
-
CONT CAB:
- indicates a DUCT TEMP OVERHEAT OR
- failure of the primary AND secondary temp controllers
- if this happens - [ZONE TEMP] can NOT be reset
-
FWD / AFT CAB:
- indicates ONLY duct temp overheat
Note:
- any failure affecting the supply of trim air will cause the temp control system to control both pack INDEPENDENTLY
-
DUAL CHANNEL - RECALL
- CONT CAB: failure of flight deck PRI OR STBY temp controller
- FWD/AFT CAB: indicates a failure of the zone temp control
- lights extinguish when MC is reset
5
Q
ZONE TEMP Selectors
A
OFF:
- closes the associated trim air modulating valve
- sets a fixed cabin temp for flt deck (75’F) and cabin (65’F)
- Note: placing all 3 selectors to OFF with the new pack flow temp controller and eFLOW valve will cause a fault that must be cleared by Maint.
- if any selector is turned OFF - it is then ignored by the temp controllers with same (low temp) logic
AUTO:
- provides automatic temp control for the associated zones
- manually rotating to C or W manually sets the desired temps
C = 65’F W=85’F