1
Q

When you are using any refrigerant or working on an air conditioning system, you must always wear:
a. safety glasses
b. safety glasses with side shields
c. a face shield
d. one of the above mentioned methods of eye protection.

A

d. one of the above mentioned methods of eye protection.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The maximum allowable filling limit for any refrigerant container is:
a. 65% of it’s internal volume
b. 75% of it’s internal volume
c. 80% of it’s internal volume
d. 90% of it’s’ internal volume

A

c. 80% of it’s internal volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A refrigerant identifier (vapor analyzer) is a diagnostic instrument designed to evaluate vapor samples directly from the air conditioning system. The analyzer is able to:
a. identify and measure the purity of air conditioning system refrigerants.
b. determine the percentage of air ( a non condensable gas) contained in the air conditioning system.
c. prevent the filling of refrigerant recovery bottles with mixtures of refrigerants.
d. all of the above

A

d. all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The manifold gauge set’s __________ register the pressure in the range of 0-150 psi, which is present in the left hand hose.

A

low pressure (blue)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The purpose of using a high-capacity vacuum pump when servicing an air conditioning system is to remove the moisture and air that is hidden in the hoses and components of a closed air conditioning system.
True
False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When exposed to an open flame, refrigerants that contain fluorocarbons break down and produce:
a. a cooling effect.
b. dangerous poisonous vapors.
c. hydrocarbon based refrigerants.
d. water vapour and steam.

A

b. dangerous poisonous vapors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

It is acceptable to recover different types of refrigerants into the same container, as long as you can re-use it afterwards.
True
False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The manifold gauge set’s _______________ registers the pressure registers the pressure

A

High pressure gage (RED)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The manifold gauge set’s center mounted utility hose can be used to:

A

a. recover refrigerant from the system.
b. pressure test the a/c system.
c. Recharge the a/c system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A micron gauge can be used to accurately measure ___________________ that has been reached in the air conditioning system as it is being evacuated.

A

the level of vacuum.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If a bubble crimp produced on a bead lock fitting is properly centered and looks regular, you can check it’s accuracy with the use of a ____________.

A

micrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The bent fins of the air conditioning condenser and evaporator can be straightened by the use of a __________.

A

fin comb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A damaged or loose __________________ can cause a refrigerant leak large enough to render an air conditioning system useless in a matter of hours.

A

schrader valve core

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Quality troubleshooting and service procedures always start with a ___________ of the HVAC system.

A

visual inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The first step in diagnosing the source of an HVAC cooling problem is to ______________

A

gather information

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the HVAC visual inspection has eliminated the cab heating system from being the cause of the cooling malfunction, but has not helped to isolate the air condition problem, you should conduct an air conditioning system ________________

A

performance test

17
Q

Properly operating air conditioning system temperature and pressures vary with ________________________

A

ambient temperature, humidity levels and condenser size.

18
Q

If a blockage to refrigerant flow (internal restriction) occurs inside the air conditioning system, ________ system pressures will result.

A

low

19
Q

A malfunctioning air conditioning _________ will cause you to observe higher than normal low side pressure readings, lower than normal high side pressure readings and high temperature readings in HVAC duct airflows.

A

compressor

20
Q

__________ pressure readings can be caused by two or more refrigerants mixed inside the air conditioning system.

A

High

21
Q

Dirt and debris lodged in the condenser fins will cause ___________________ operating air conditioning system pressure readings.

A

higher than normal.