Air Conditioning, Pressurization and Pneumatics Flashcards
What is the purpose of the ECU?
Regulates bleed air flow rate and pres for air conditioning, pressurization and deicing.
What is normal max dif?
When will the safety valve open?
When is neg relief provided?
What is max cabin altitude?
When does the “Cabin Pres” warning light come on?
- 46 psi
- 8 +/-0.15 psi
- .5 psi
8000 ft
9800 ft
What is takeoff memorization mode?
Pressurization controller stays in takeoff mode for 10 minutes after takeoff or 5000 above field altitude, whichever occurs first.
This facilitates a return to the departure airport.
What does the cabin pressurize to if bleeds are on, when still on the ground?
When?
What rate?
400 ft below aircraft altitude.
PLA > 60°
400 ft/min
How are outflow valves operated?
Opened pneumatically and closed by spring.
What happens when you make a temp selection?
TSOV and bypass valve are modulated at the same time
What happens when a temp selection is made towards cool?
The ECU modulates the pack bypass valves to add warm air to the cold air coming off the turbines.
*It closes restricting warm air from mixing.
What happens if a pack overheats?
- Computer takes it offline.
- Flow will go to norm or hi automatically.
Remaining pack handles 70%
What does the environmental system provide?
Pressurization, heating, cooling and ventilation.
What are the two air conditioning modes?
What is the difference?
What happens if both digital and analogue channels fail on one side?
Analogue and automatic
There is no protection on analogue
You will not get a “Bleed Hot” caution light as one channel has to be functioning. So you get no indication of over temp or over pressure.
When does the “Bleed Hot” caution light come on?
What is the result?
When there is an over temp, an over pressure or a leak at 180°C in bleed ducts in between the duct and shroud.
The bleed air system automatically shuts down. (HPSOV, P2.2 cooling valve and PRSOV shuts off)
Which valves will be open at low power and bleeds on?
If bleeds are on and engine power setting is low, where is bleed air coming from?
If bleeds are on and engine power is high, where is bleed air coming from?
What happens to these valves in the event of loss of electrical power?
HPSOV and Nacelle FCSOV
HP compressor. (P3.0 or HPSOV)
LP compressor. (P2.7)
They will failsafe close.
What speed does the recirc fan run at when only one bleed pack is selected?
What will be the flow rate compared to two pack operation if only one pack is working?
Low
70% of two pack operation.
What is the temperature range the ECU keeps in the supply ducts?
2.8°C to 71 °C
When in AUTO control what temperature does the ECU regulate the cabin to? How
What does MAN selection do? What is the temp range? When is it used.
Coldest: 15°C - full counter clockwise
Warmest: 27°C - full clockwise.
It determines what the duct temperature should be in order to achieve the desired temperature. Therefore, disregard temperatures of duct when in AUTO.
MAN selection controls duct temperature between 3 °C to 71°C. Duct temperatures need to be monitored more closely in MAN mode. It’s used only when AUTO mode fails.