After Thoughts Flashcards
What is the interlock with both CCP breakers open?
LD Orifice Valves will close
QRV-160, 161, and 162
What will close the LD Orifice Valves? (4 things)
Phase A
When either LD Isolation Valve is closed
Loss of both CCPs
PRZ Level at 17%
What is the interlock to open the LD Isolation Valves?
Will not open if any orifice isolation valve is open
What is the interlock with IMO-128?
NPS-122, Loop 1, Ch 3
What is the interlock with ICM-129?
NPS-121, Loop 2, Ch2
After swap to CL Recirc, how long do you have to isolated the SAT?
5 minutes to keep the NAOH from messing up the pH
How do you adjust the temperature for the H2 Recombiners?
Adjust the KW
What is the MFP low condenser vacuum trip?
U1 = 20” Hg
U2 = 20.3” Hg
What is the MFP Low Lube Oil pressure trip?
4# with a 5 second time delay
What is the Low Suction pressure MFP Trip?
180# with a 5 sec time delay
What is the Low Pressure auto start for CCW?
80#
What is the low pressure auto start for ESW?
40#
What is the Low Pressure auto start for NESW?
U1 = 55#
U2 = 60#
What are the design features to prevent SFP from draining?
No Gravity Drains
Suction’s 19.5” below surface
Return Lines > 6’ above fuel
Anti-Siphone Holes 4” below surface
Skimmer 6” below normal surface
What is the low pressure autostart for the CBP?
325#
What is the low pressure auto start for the hotwell pumps?
130# for unit 1
110# for unit 2
RCDT Inputs?
Accumulator Drains
RCS Loop Drains
Regen and XS LD HX Drains
RX Vessel Flange Leakoff
Refueling cavity
What is the U1 Turbine Low Vac Trip from DCS?
22.5” Hg at 100% power
What is the U1 Turbine Trip from Low Oil Pressure?
8 psig for > 5 secs
What is the U2 Turbine Trip from Low Vacuum?
22.5” Hg at 100% power
What is the U2 TUrbine Trip from Low Oil Pressure?
14.7 psig for > 5 secs
What is the input to the RIL Computer?
Auctioneered high Delta T
What are the PRT Inputs?
Seal Return Safety
ECCS Safeties
RHR Suction, HL Discharge and Hx Safeties
CCP Safeties
What temperature does the Turbine Trip Steam Dump controller control at?
547* F
What temperature does the Load Rejection Controller control at?
552* F
Rods take care of the other 5*
What is the input for the MFP DP Setpoint?
Total Steam Flow
What is the alternate power supply for the CRIDs?
600V thru the Isolimeter
If the CRID is on the alternate source of power (600 V), what is the status of the Inverter and Bus?
Inverter = INOP
Bus = OPERABLE
If the CRID is on CRP-3 power source, what is the status of the CRID Bus?
INOP
What’s the MS pressures for U1 and U2 at 50% power?
U2 will be higher than U1 due to the higher temperature at which it operates
Steam dumps are in steam pressure mode and fail open. What is the minimum action to stop the cooldown involving the switches?
Take 1 switch to off
What’s the basis of the 46K FO Storage Tank Tech Spec?
1 EDG for 7 Days
What is a DAC hour?
1 DAC Hr = 2.5 mrem
How does IRV-311 fail on a loss of CA?
Open
A High rad on which Rad Monitor meets entry Conditions for Irradiated Fuel Handling Accident in Containment - Control Room Actions?
VRS-1500, Vent Stack
What are the SC requirements during NC with and without CRDMs?
90*F with CRDMs
220*F without CRDMs
What would result in immediate suspension of core alts?
Loss of comms between the Control Room and Fuel Handling People
When evacuating the CR, how is CVCS cross-tie done and how is it monitored?
Opp Unit CCP suction to the RWST. Flow is tracked by the U1/2 cross-tie flow indicator
How does the AEO Trip the Rx Locally in FRS-1?
Rx Trip Breakers
Rx Trip Bypass Breakers
MG Set Output Breakers (2)
Has significant fuel damage occurred when CETs are at 1200*F?
No
Which procedures can you transition to from the immediate actions of E-0?
ES-0.1 if SI is not actuated or required
ECA-0.0 if no power to either A or D T bus
FR-S.1 if Rx Trip is unsuccessful
What is the order of preference for depressurization in ES-1.2, Post LOCA Cooldown and Depressurization?
- Normal Spray
- PORV
- Aux Spray
What is indicative of a RCP Thermal Barrier Hx Failure?
RCP Alarms
CCW Surge Tank Level Rising
RCP Cooling water flow mismatch
Which pump is the CCW Misc Hdr aligned to first when splitting trains out to identify the leak?
East
What is used to determine with PRZ PORV is leaking?
Rising PORV Discharge Temp
During a SG Tube Leak, when would you trip the RX and SI?
RCS SC < 40*F
PRZ Level is not able to be maintained
SG Tube Leak of > 100 gpm
What are the indications of #1 RCP Seal Failure?
1 Seal DP LOwering
SLO Flow Lowering or Raising (depending)
Lower Bearing Water Temp Rising
What are the indications of a # 2 Seal Failure?
1 SLO Flow Lowering (usually) or Rising
RCDT Level / Temp Rising
RCP Standpipe Level High
Vibes rising
If you lose a Train of 250 VDC, what will cause a Reactor Trip?
RCP Bus UF / UV
A loss of which train 250 V DC will NOT trip the generator and why?
Train A bc it powers 33 VED
Which Tain of 250 VDC powers annunciators?
Train A
A loss of which train of 250 VDC will cause all 9 steam dump valves to be blocked closed?
Either Train