AFD Hoses Flashcards

1
Q

AFD Hoses

A
  • 1 3/4’ attack lines, 50’ sections, 200’ crosslay
  • NO 2 1/2” supply lines
  • 100’ sections of LDH 5”, 800’ on all pumpers
  • Typically impregnate single jacket hose (polymer covered, polymer lined)
  • Pre-connected crosslays 200’
  • No booster hose
  • Test quarterly, annually, after each use
  • 200’ preconnected 2 1/2” Blitz line
  • 1000’ horseshoe rolled blitz line
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

NFPA 1901 vs. AFD

A

NFPA 1901:
15’ large, soft-sleeve hose or 20’ hard suction
800’ of 2 1/2” or larger supply hose
400’ of 1 1/2” or 1 3/4” or 2” attack hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Attack Hose Pressure Testing

A
  • Annually

- Designed for 275 psi, tested at 300 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Supply Hose Testing Pressure Testing

A
  • Annually

- Designed for 185 psi, tested at 200 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

AFD Smooth Bore Parts

A
  • Tip
  • Playpipe
  • Shutoff
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

AFD Smooth Bore Tip Size/GPM of 2 1/2” Handline

A
7/8"=160
15/16"=180
1" = 200 gpm
1 1/8" = 250 gpm
1 1/4" = 325 gpm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

AFD Master Stream Tip Size/GPM

A

1 3/8” = 500 gpm
1 1/2” = 600 gpm
1 3/4” = 800 gpm
2” = 1,000gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

AFD Fog Nozzle

A
  • SM20 Fog on 1 3/4”

- Flow 60-200 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

ADULTS

A
  • Advanced Fire Conditions
  • Defensive Ops
  • Unknown Fire Location
  • Large, Undivided Area
  • Tons of Water
  • Sprinkler or Standpipes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly