70206 Flashcards
what was the quote # for 70206
24818DQ
what are the tank dimensions?
205’ x 59’ CRT
where is the job located?
Jackson LA
What is the site address?
1476 US-61 Jackson, LA 70748
What is the tank #?
1518
what is scope item 3.1.1.
mobilize crew and equipment
what is scope item 3.1.2.
install new repair nameplate
what is scope item 3.1.3.
remove and replace 6” of sand inside ringwall
3.1.3.a. what are the client supplied sand specs?
Remove and replace a Clean washed sand or sand equivalent per ASTM D2419 (25 minimum)
Grain Size: ASTM C136 Sieve Analysis of Fine and Coarse Aggregates
Sieve Size Wt. % Passing
3/8” 100%
#4 95%-100%
#50 10%-40%
#100 3%-20%
#200 0%-15%
Chlorides: ASTM D512 (Method C), < 10 ppm
Sulfides: EPA 376.1, < 1.00 ppm
pH: ASTM G51, 5.5 < pH < 1
Resistivity: ASTM G57, > 10,000 ohm-cm saturated
how many allowance man hours do we have on the job total?
2,179
how many allowance hours do we have for hw/fw?
363
when are we scheduled to finish the project?
10/7/2024
what does scope item 3.1.3.b state?
Samples of the new sand will be collected and supplied to the client lab per the client-supplied specification: MS-13-18 Above Ground Storage Tank Floor and Pipeline Padding Materials (Contractor) (12596_1). The test results must be supplied back to Tarsco within forty-eight (48) hours of the samples being mailed.
how many allowance manhours total do we have on the job?
2,542
what is scope item 3.1.4.?
Install a new 5/16” thick A-36 bottom. The existing bottom is to be removed by others prior to mobilization to the site. The existing annular ring and bottom sump will remain in place. Additional charges may be incurred if the existing annular plate and bottom sump are unsuitable for installing the new tank bottom plates.
what is scope item 3.1.5.?
3.1.5. Time has been included for the client’s QA/QC representative to visually inspect both sides of each bottom plate. Tarsco will flip the bottom plates for this inspection, two (2) minutes per each side of each plate has been included.