After a BA wear what are the cool down rules
Warm wear 30mins/500ml cold water
Hot wear 60mins/1000ml water
What has replaced BA Main Control and what’s the minimum rank
BA sector
SC
Re entry rules (3)
Closed down set
Redeployment to complete specific task not FF
190 bar/15 min duration
When can 1 BA wearer work (4)
Car/rubbish fire
Working at head of aerial appliance
Not within building structure
In view of IC
Actions if BA telemetry and radio signal lost
Withdraw to point of regaining. Landmark. Request telemetry repeaters
Low battery warning at entry control
And in a job
Actions
Before entry take set out of service
During a wear inform eco. Continue. Then take out of service after
Minimum rank of BA team leader
Competent FF
Low pressure warning whistle operates at….
Sdba
12 mins
50 lpm
Edba
18 mins
58 lpm
GTS working duration
20mins unless agreed longer
Stage 1 GTS rule
In sight of the ECO
Stage 2 GTS rule
When wearers not in sight of ECO
What must you do when donning BA for high Ex foam
Take rubber casing off the lung demand valve
Can other agencies wear BA with LFB
Yes if they have all their own gear (ECB/BA)
HART EDBA may use LFB ECB**
When should IC consider BA comms (pumps)
4 pumps and above