3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM Flashcards

1
Q

What is the LCO and APPLICABILITY for Technical Specification 3.5.1, ECCS-Operating?

A

LCO: Each ECCS injection/spray subsystem and the Automatic Depressurization System (ADS) function of eight safety/relief valves shall be OPERABLE.

APPLICABILITY:
MODE 1
MODES 2 and 3, except ADS valves are not required to be OPERABLE with reactor steam dome pressure less than or equal to 150 psig.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the one hour, or less, actions associated with Technical Specification 3.5.1, ECCS-Operating?

A

Condition B: High Pressure Core Spray (HPCS) System Inoperable - Verify by administrative means RCIC System is OPERABLE when RCIC is required to be OPERABLE - 1 hour

Condition H:
HPCS and Low Pressure Core Spray Systems Inoperable
OR
Three or more ECCS Injection/spray subsystems Inoperable
OR
HPCS System and one or more ADS valves Inoperable
OR
Two or more ECCS injection/spray subsystems and one or more ADS valves inoperable

  • ENTER LCO 3.0.3 Immediately
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the LCO and APPLICABILITY of Technical Specification 3.5.2, ECCS-Shutdown?

A

LCO: Two ECCS injection/spray subsystems shall be Operable

APPLICABILITY:
MODE 4
MODE 5 except with the reactor vessel head and steam dryer storage/reactor well gate removed and water level greater than or equal to 22 ft 9 inches over the top of the reactor pressure vessel flange.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the one hour, or less, actions associated with Technical Specification 3.5.2, ECCS-Shutdown?

A

Condition C: Two required ECCS injection/spray subsystems inoperable - Initiate action to suspend OPDRVS - Immediately AND Restore one ECCS injection/spray subsystem to OPERABLE status - 4 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the LCO and APPLICABILITY of Technical Specification 3.5.3, RCIC System?

A

LCO: The RCIC System shall be OPERABLE

APPLICABILITY:
MODE 1
MODES 2 and 3 with reactor steam dome pressure >150 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the one hour, or less, actions associated with Technical Specification 3.5.3, RCIC System?

A

Condition A: RCIC System inoperable - Verify by administrative means High Pressure Core Spray System is OPERABLE - 1 hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly