3.2 POWER DISTRIBUTION LIMITS Flashcards
What is the LCO and APPLICABILITY of Technical Specification 3.2.1, AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)?
LCO: All APLHGRs shall be less than or equal to the limits specified in the COLR.
APPLICABILITY: THERMAL POWER greater than or equal to 23.8%
What are the one hour, or less, actions associated with Technical Specification 3.2.1, AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)?
NONE
What is the LCO and APPLICABILITY of Technical Specification 3.2.2, MINIMUM CRITICAL POWER RATIO (MCPR)?
LCO: All MCPRs shall be greater than or equal to the MCPR operating limits specified in the COLR.
APPLICABILITY: THERMAL POWER greater than or equal to 23.8%
What are the one hour, or less, actions associated with Technical Specification 3.2.2, MINIMUM CRITICAL POWER RATION (MCPR)?
NONE
What is the LCO and APPLICABILITY of Technical Specification 3.2.3, LINEAR HEAT GENERATION RATE (LHGR)?
LCO: All LHGRs shall be less than or equal to the limits specified in the COLR.
APPLICABILITY: THERMAL POWER greater than or equal to 23.8%
What are the one hour, or less, actions associated with Technical Specification 3.2.3, LINEAR HEAT GENERATION RATE (LHGR)?
NONE