3 Even | VENTILATION Panel Flashcards
When would a pilot select the EXTRACT to OVRD?
- Heavy Rain on the ground
- When directed to by the ECAM
What are some potential causes for the illumination of the BLOWER FAULT pb light?
- Low blower pressure
- Duct overheat
- Computer power supply failure
- Smoke warning activated
What are some potential causes for the illumination of the EXTRACT FAULT light?
- Low extract pressure
- Computer power supply failure
- Smoke warning activated
What condition in the avionics ventilation system would cause an external horn to sound?
BLOWER FAULT or EXTRACT FAULT on the ground with both engines stopped.
Describe the avionics ventilation system.
It is a fully automated system that considers the skin temperature and adjusts inlet and outlet flaps to optimize cooling and airflow.
During normal operations, the AIR COND INLET VALVE remains in which position?
Closed
What is the OPEN CIRCUIT CONFIGURATION of the avionics ventilation system?
Both the inlet and the outlet flaps are fully open (aircraft is on ground and the skin temperature is above a set threshold)
What is the CLOSED CIRCUIT CONFIGURATION of the avionics ventilation system?
Both the inlet and outlet flaps are fully closed. The SKIN EXCHANGE INLET BYPASS VALVE and SKIN EXCHANGE ISOLATION VALVE is open, allowing air to the cargo under floor, eventually exiting via the outflow valve (aircraft is on the ground or inflight and the skin temperature below a set threshold).
What is the INTERMEDIATE CIRCUIT CONFIGURATION of the avionics ventilation system?
The inlet flap is fully closed, the outlet small flap is open (aircraft is in-flight and the skin temperature is above a set threshold).
During abnormal operations, the AIR COND INLET VALVE remains in which position?
Always opens to provide fresh ventilation air
What is a BLOWER or EXTRACT FAULT?
Both inlet and outlet flaps are fully closed, SKIN EXCHANGE INLET BYPASS VALVE closed.
What is the SMOKE CONFIGURATION for the ventilation system?
Once the BLOWER and EXTRACT pushbuttons have been selected to OVRD, the blower fan will stop, the extract fan will continue to run. The inlet flap closes, the small outlet flap opens, the SKIN EXCHANGE ISOLATION VALVE closes and the SKIN EXCHANGE INLET BYPASS VALVE closes.