15.20 Flashcards
What type of switch is a spot sensor?
Bi metallic
What type of loops are used for fire detection?
Continuous
What are the 2 continuous loops that can be used?
Semiconductor, pneumatic
Pneumatic pressure loop is called?
Systron and donner loop
In a control unit describe the contacts relationships with resistance and condition
High resistance is normal condition, low resistance is alarm condition
How many sensors are in a dual loop system?
2
What does a ceramic material function as?
Endless number of resistors
How long after a fault will the pilot receive a loop fault message?
15 seconds
The fire extinguishing system uses what agent?
Halon 1301
What pressure is halon at? And what is it pressurised by?
600 psi, nitrogen
What are the different weights of fire bottles and where are they?
Cargo - 20kg
Engine - 10kg
APU - 5kg
How much explosive powder is in the discharge cartridge?
400 milligrams
What is the maximum service life of the discharge cartridge?
6 years
What is the maximum storage life of a discharge cartridge?
10 years
When does the bottle light come on in the cockpit?
When bottled pressure goes below 50% of normal pressure