13. EMER ELEC PWR Panel Flashcards

1
Q

What powers the emergency generator?

A

Blue hydraulic system pressure generated by the RAT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When does the RAT automatically deploy?

A

Inflight with a loss of power to AC Bus 1 and 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the source of power during RAT deployment and approximately how long does it take?

A

The aircraft batteries are the sole source of electrical power for the AC and DC Essential Buses until the EMER GEN is online, which takes between 5‐10 seconds.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does the red FAULT light on the RAT & EMER GEN pb indicate?

A

The EMER GEN is not supplying power to AC and DC Essential busses.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does the SMOKE light in the GEN 1 LINE pb indicate?

A

Smoke detected in the avionics ventilation ducting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Will there be any other indications of avionics smoke on the overhead panel?

A

FAULT lights in the EXTRACT and BLOWER PBs on the VENTILATION panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens when you push the GEN 1 LINE pb to OFF?

A

Generator 1 is isolated from the electrical system network and is only providing power to one fuel pump in each wing fuel tank.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When is this procedure used?

A

Smoke procedures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Is there a way to manually deploy the RAT?

A

Yes, the guarded MAN ON pb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Will the RAT deploy on the ground if this button is pressed?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Do pilots ever use the EMER GEN TEST pb?

A

No – maintenance function only