11.15 - Oxygen Flashcards

1
Q

Where is the crew oxygen regulator located

A

As close to the bottle as possible to avoid/reduce the amount of high pressure lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

On inspection, the crew oxygen bottle shows 1680psi when it should show 1850psi. What should you do

A

Consult charging chart as pressure depends on temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When does oxygen flow to the oxygen generator masks

A

When the mask is pulled downwards from the passenger service unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How can the oxygen flow into the crew oxygen mask be tested without removing the mask from its stowage

A

By moving the press to test button and watching the oxygen flow indicator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If you inspect an oxygen storage bottle and find that the pressure is 75psi. What should you do

A

Re charge the bottle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many oxygen masks are there per number seats in the row

A

One more than the number of seats in case there is a child sharing its parents seat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What normally activates the passenger oxygen system

A

A pressure switch which senses the cabin pressure (cabin altitude)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What safety precautions should be strictly adhered to when working on oxygen systems

A

Use no oil or grease, keep clean and handle with care

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How can maintenance be carried out on individual passenger oxygen masks

A

The units can be opened individually by using a special tool

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If you inspect an oxygen storage bottle and find that the pressure is 75 psi, which section should you take

A

Recharge the bottle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How can you tell that a chemical oxygen generator has been used

A

By checking a temperature sensitive decal on the unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly