Electrical: Which power sources can supply power to the bus bar?
- Starter-generator (28.5V - 4.8KW)
- Battery (24V - 16Ah)
- External Power Unit (28.5V)
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.1)
Electrical: What is the relation between the three power sources?
External Power Supply:
- BAT cannot cut-in
- GEN cannot cut-in, but can be operated as a starter
Generator Supply:
- When engine running
- Charging battery
Battery Supply:
- When GEN voltage drops below BAT voltage
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.1)
Electrical: What happens if <CUT OFF> push-button is pressed on the honeywell panel?
Cut-out BAT and GEN power supply simultaneously
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.2)
Electrical: What is the purpose of the voltage regulator?
Maintains the generator voltage to 28.5 V ± 0.25 V
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.2)
Electrical: What happens in case of an overvoltage (>31.5V)
GEN is isolated from the bus bar
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.2)
Electrical: What does the BAT and GEN lights indicate when illuminated?
Comes on to indicate cutting-out of the corresponding power source
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.2)
Electrical: When does the BAT.T warning light illuminate?
When battery internal temperature exceeds 71°C
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.2)
Electrical: At which voltage is the GEN cut-in?
When generator voltage exceeds the bus bar voltage by 0.5V
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.4.3)
Electrical: What is the purpose of the inverter?
DC power → AC power
Supplies:
- Autopilot
- Radionavigation equipment
Electrical: Where is the main battery and the battery for the STDBY-Horizon located?
- Battery: Right hand hold
- STDBY-Horizon battery: Left hand hold
Electrical: What is the function of the <GEN R> push-button on the honeywell panel?
Couples GEN to bus bar at the correct voltage.
- A time delay prevents resetting immidiately after an electrical fault
(Instruction Manual - Basic 1 - Main Systems, Chapter 7, Paragraph 7.4.6)