1
Q
If the upper DU knob is selected to OFF what will occur?
A
- The E/WD display would automatically transfer to the “lower” display.
2
Q
With the E/WD displayed on the “lower” screen, what steps should be taken to view SD information?
A
- Press and hold the appropriate system button on the ECAM CONTROL panel. The information selected will be available for 30 seconds.
3
Q
What does the ALL pushbutton do on the ECAM control panel?
A
- Displays ALL the system pages successively in 3-second intervals when held down
- Release the pushbutton to maintain display of the selected page
4
Q
What does pressing the RCL pushbutton do?
A
- Allows the flight crew to review any warning or caution messages that the CLR pushbutton or flight phase inhibition may have suppressed
- If held longer than 3 seconds, the E/WD will show any caution messages suppressed by the EMER CANC pushbutton
5
Q
If the STS pushbutton is pressed and the system has no STATUS messages, what will be displayed?
A
- “NORMAL” for 5 seconds
6
Q
What occurs during the Before Takeoff Flow when the T.O. CONFIG
pushbutton is pressed?
A
- The system simulates the application of takeoff power and checks certain systems for proper configuration
- A warning is displayed if a system is not configured properly
- “TO CONFIG NORMAL” is displayed in the TO MEMO section if the configuration is correct
7
Q
What does the EMER CANC accomplish?
A
- Cancels the audio for warning messages (without removing any ECAM message)
- Cancels the present caution for the rest of the flight
- Calls up the STATUS page, which displays “CANCELLED CAUTION” and the TITLE of the failure
- Inhibited message can be recalled by holding RCL for more than three seconds
8
Q
What is the purpose of having the EMER CANC pushbutton?
A
- Used to cancel spurious MASTER CAUTIONS