1 1/4 School Church and Day Nursery Inspection Flashcards
Field personnel are responsible for conducting fire prevention inspections of churches (____) in their districts.
under occupant load of 750
Before you begin your inspection tour, request that a fire drill (_____) be conducted for you to observe.
E-occupancies
When problems are encountered in public schools that cannot be resolved by discussing them with the principal, contact the _______, telephone No. 213 743-5086.
Supervisor, Environmental & Health and Safety, Business Division of the Los Angeles Board of Education
AISLE : An exitway, at least ____ providing a means of egress from a seating area or an area of booths, exhibits, or other equipment.
3’ wide
AISLE ACCESSWAY : A pathway of less than___, providing a means of egress from among seats, to an aisle.
3’ in width
ASSEMBLAGE : Any room or area where more ____ gather for any purpose.
than 50 people
BASEMENT : Any story in which the surface of the floor above is less than ____ the adjacent ground elevation at all points.
6’ above
DAY NURSERY : Any non-residential building used for day care purposes for more than ___ and any residential building used for day care purposes for more than _____.
six children / 12 children
SAFETY CAN : An approved container of not ____ capacity, having a self-closing lid and spout cover and designed to safely relieve internal pressure when subjected to fire exposure.
over 5 gallons
ELEMENTARY: One that has all of the grades from_____ and a curriculum under the jurisdiction of the Board of Education.
first through sixth
PAROCHIAL: A school, the curriculum of which is under the jurisdiction of the State Board of Education, and which is financed by a _____.
religious group
PRIVATE: A school, the curriculum of which is under the jurisdiction of the State Board of Education, and which is financed by other than a _______.
religious group or by State funds.
PUBLIC: A school, the curriculum of which is under the jurisdiction of the State Board of Education, and which is financed by ____.
State funds.
STAGE: A partially enclosed portion of an assemblage occupancy which is designed or used for the presentation of plays, demonstrations, or other entertainment, wherein scenery, drapes, or other effects may be installed or used, and where the distance between the top of the proscenium opening and the ceiling above the stage is more ____.
than 5 feet.
Storage : Paper from paper drives shall not be stored ____ of any structure.
within 10’
Containers for materials subject to spontaneous heating shall be on noncombustible stands if not resting on the ground or on a noncombustible floor, and shall be kept ____ from combustible walls and exterior window openings.
at least 2’
Appliances
1. Portable - 57.113.15 - Shall not be placed closer than ____ to wash basins, bathtubs, showers or other grounded surfaces.
5’
Exit Signs
2. Lamps - 1013.3 UBC - When required to be lighted, shall be lighted with two electric lamps of not less than ____ from each lamp.
5 foot candle
Extension Cords
3. Extension Of - 57.20.37 - Shall not be extended, spliced or repaired so as to exceed their original length, nor extended from _____.
one room to another.
Panel
8. Clearance - POLICY - 57.57.06 - a _____ is required in front of all electrical panels. No storage of combustibles in electrical panel room.
3’ clearance