Zone Controls for Heating Flashcards

1
Q

What is a zone?

A

A section of a building, heated or cooled, controlled by a thermostat.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are 3 reasons to zone a house?

A
  1. To have more control over the temperature of each room in a house.
  2. To make a house more comfortable.
  3. To save money on heating or cooling.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Zoning can be done with what types of heating systems?

A
  1. Hot Water baseboard
  2. Steam
  3. Hot air
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When zoning with circulators, each zone needs what 4 things?

A
  1. a separate circulator
  2. a flow check valve
  3. a relay
  4. thermostat
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Zoning with zone valves:
Each zone needs 3 things:

A
  1. a zone valve
  2. a thermostat
  3. one circulator (properly sized)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Zoning with zone valves for 3 or more zones:
Each zone needs 4 things…

A
  1. a zone valve
  2. a thermostat
  3. one circulator (properly sized)
  4. a 24 volt 40 VA transformer (Transformer properly sized for all zones connected)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Relays are used for what?

A

to energize the circulator and burner circuits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

RA 832A is used for what type of systems?

A

millivolts systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

RA 845A is used for what type of systems?

A

24 volt systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Multiple zones are best controlled by ________?

A

a relay pack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

RA 832A Relay Connections:

T-T connects to ____
X-X connects to ____, and what kind of switch?
1-2 connects to ____
2-3 connects to ____, and
(Which is hot and which is neutral?)
2-4 connects to ____
and (Which is hot and which is neutral?)

1-3 are ____ contacts and connect to ____ volts.
1-4 are ____ contacts and connect to ________ volts.

A

RA 832A Relay Connections:

T-T to thermostat
X-X to T-T on Aquastat and is an end switch
1-2 to 120 volt power system
2-3 to circulator
(2 is neutral, and 3 is hot)
2-4 to optimal load 2nd load,
(4 is hot, 2 is neutral)

1-3 N/O connect to 120 volts
1-4 N/O connect to 120 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

RA 845A Relay Connections:

T-T connects to
1-2 connects to
4 connects to 1 for what reason?
4 and 3 are ______ contacts.
3 connects to hot on ________ and needs a neutral from_______.
5-6 are _______ contacts

A

RA 845A Relay Connections:

T-T connects to the thermostat
1-2 connects to 120 volt power input
4 connects to 1 as a jumper for 120 V
4 and 3 are N/O contacts
circulator,
and needs a neutral from 2
5 and 6 are N/O contacts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Relay packs only require _________ input once.

A

120 volt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Relay packs have built in priority for _________.

A

indirect heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Relay packs have how many zones per relay?

A

2-6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Relay packs with built in priority for an indirect heater serves what purpose?

A

To shut off all other zones to make hot water.

17
Q

A relay pack has end switch contacts which get wired to _____________________.

A

T-T on aquastat

18
Q

Erie Zone Valves:
red wires go to ______
black wires do what?

A

red: T-T on aquastat boiler
black: power motor through a 24v transformer

19
Q

Honeywell V8043F
end switch X-X gets wired to
TH
TR
TH/TR

A

end switch to T-T on aquastat
TH to thermostat
TR to transformer
TH/TR may not be used unless as a splice/wirenut