waste disposal- Plastic process machine Flashcards

1
Q

when carrying out an COSHH assessment what information should be referred to ?

A
  • JSP 395(F)
  • Hazard data sheets
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what os the function of the plastic processing machine?

A

to reduce the volume of ships waste (PLASTIC) by means of shredding, heating and compaction, to form a sealed ‘slug’ prior to disposal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

discribe the air cooling system?

A

once the plastic is compacted against the gate, heating elements mounted in the compactor ram head, compactor chamber and gate are energised to heat the plastic easte to a temperature of 200 degrees

after pre-determined time the heaters are switched off and a fa blows cooling air over the heated areas until the temperature drops to approximately 70 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

list the fault indications

A
  • shredder fault
  • compactor fault
  • gate fault
  • gate clamp fault
  • diverted fault
  • heater fault
  • continuous monitoring fault
  • infra-red sensor fault
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

what are the heater over temperature warnings ?

A

RAM HEAD HEATER HIGH TEMP- red- 220 degrees
BARREL HEATER HIGH TEMP - red- 220 degrees
GATE HEATER HIGH TEMP - red- 220 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

what are the miscellaneous alarms and warnings

A
  • slug cooling - amber
  • system fault -amber
  • motor overheat - red
  • fluid low -amber
  • waste required
  • remove slug
  • rest
  • start process
  • part slug
  • lamp test
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

explain the air cooling system process

A
  • the air cooling system consist is of continuous running air blowing, a diverter flap valve and associated trunking and hoses
  • the air cooling system extracts fumes from the hopper and chamber barrel or via the diverter flap vlave it can divert the air flow ro cool the heaters and slug
  • cooling of the slug is achieved by pulling air over the slug and into the filter located in the base unit
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

to enable access to the compaction chamber, the machine has to be reconfigured using the MAINTAINERS SWITCH, what are the three positions?

A

OFF
open chamber
heat/spray

How well did you know this?
1
Not at all
2
3
4
5
Perfectly