VENTILATION Panel Flashcards

1
Q

What are some potential causes for the illumination of the BLOWER FAULT light?

A

• Low blower pressure • Duct overheat • Computer power supply failure • Smoke warning activated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are some potential causes for the illumination of the EXTRACT FAULT light?

A

• Low extract pressure • Computer power supply failure • Smoke warning activated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What condition in the avionics ventilation system would cause an external horn to sound?

A

BLOWER FAULT or EXTRACT FAULT illumination on the ground with both engines stopped.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Describe the avionics ventilation system.

A

It is a fully automated system that considers the skin temperature and adjusts inlet and outlet flaps to optimize cooling and airflow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

OPEN CIRCUIT CONFIGURATION

A

Both the inlet and the outlet flaps are fully open (aircraft is on ground and the skin temperature is above a set threshold)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

CLOSED CIRCUIT CONFIGURATION

A

Both the inlet and outlet flaps are fully closed. The SKIN EXCHANGE INLET BYPASS VALVE is open, allowing air to the cargo under floor, eventually exiting via the outflow valve (aircraft is on the ground or in-flight and the skin temperature below a set threshold).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

INTERMEDIATE CIRCUIT CONFIGURATION

A

The inlet flap is fully closed, the outlet small flap is open (aircraft is in-flight and the skin temperature is above a set threshold).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

BLOWER or EXTRACT FAULT

A

Both inlet and outlet flaps are fully closed, SKIN EXCHANGE INLET BYPASS VALVE closed.

BLOWER Fault:

  • C – Computer power supply failure
  • L - Low blower pressure
  • S – Smoke warning activated
  • D – Duct overheat

EXTRACT Fault:

  • C – Computer Power Supply Failure
  • L – Low extract pressure
  • S – Smoke warning activated
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SMOKE CONFIGURATION

A

Once the BLOWER and EXTRACT pushbuttons have been selected to OVRD, the blower fan will stop, the extract fan will continue to run. The inlet flap closes, the small outlet flap opens, the SKIN EXCHANGE ISOLATION VALVE closes and the SKIN EXCHANGE INLET BYPASS VALVE closes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When would a pilot select the EXTRACT to OVRD?

A
  • Heavy rain on the ground
  • When directed by the ECAM
How well did you know this?
1
Not at all
2
3
4
5
Perfectly