When cutting wires attached to a building, use the following safeguards, except:
A. We’re full PPEs protective goggles, must be worn consider doing SCBA
B. Use mechanical axe with rubber gauntlet gloves
C. Stand on dry object walk in when working on a ladder.
D. Cut the closest conductor first when cutting do not touch any other conductor or a ground.
E. Be sure all insulated wires leading to the service are cut
D
The apparatus is not insulated from the ground by the rubber tires, and may be energized by live wires in the following ways, except
A. By touching an object that is in contact with a live conductor.
B. By being in close proximity to alive conductor.
C. My direct contact the live conductor.
D. By way of an extended aerial ladder, touching a live conductor.
B
Ariel ladders must be kept at least________ Feet away from all powerlines in devices
7
10
15
25
10
Guidelines for raising ladders at incidents where electrical hazards exist except
A. Keep ground ladders, at least 3 feet from wires
B. All membership identify the presence of overhead wires transformers.
C. What tops of ladders being raised for potential hazards
D. Be aware of any conditions that may cause that are slippery slide and contact electrical source.
E. Because of hand tools used on ladders
A
Although water is not a good conductor, incident, such as sheared hydrants were large volumes of water are contacting, high-voltage lines should be approached with care. The following procedure should guide first responders actions, except….
A. Spot apparatus a distance from hazard.
B. Be cognizant of high-voltage lines impacted by water from a shared hydrant may arc or fall
C. All member should be alert for additional downed wires, energized exposures
D. Denied entry to scene, locate shut off valve, mitigate threat.
E. Unless a life hazard exist notify an 08 arrival of LA DWP personnel.
D
Although injuries to firefighters from applying water, directly on electrical fires are rare, washrooms applied in the vicinity of high-voltage should be avoided. When hose streams must be used, the following should be adhered to except?
A. Where are possible, extinguish Monica Fire’s with dry chemical or carbon dioxide
Extinguishers
B. Utilize the strait stream the small air spaces between a drops of water in the Stream limit electrical conductance
C. Utilize the 30 33, 100 rule for using hose streams around high-voltage
D. Maintain a safe distance from the energize equipment. LA DWP recommends not approaching high-voltage closer than one body length.
E. Defensive stance let the equipment burn and protect exposures.
B
Maintain clearance a minimum of how many feet be on the outer, most wire, electrical transmission lines?
100 feet
Utilize the 30 33 100 rule when directing her streams near high-voltage in Wildland, refers to what three in order?
Utilize a 30° fog pattern, maintain a distance of at least 33 feet from the energized sources, maintain at least 100 psi to the nozzle
Never put water into a vault or down a manhole
True or false
True
What is the clearly identified method to assume that fire personnel and other responders do not enter life hazard zones?
The use of a minimum of three horizontal strands of barrier tape that state do not enter, or do not cross
What is the 4 inch supply hose friction loss per 100 feet of hose?
A. 500 Gpm - 5 lbs
B. 800 gpm- 12.4 lbs
C. 1000 gpm- 19.1 lbs
D. 1000 gpm- 10 lbs
A
B
C
What is the 4 inch supply hose friction loss per 100 feet of hose?
A. 1250 Gpm - 29.5lbs
B.1500 gpm- 42.3
C.1800 gpm- 50.1
D. 2000 gpm- 75.5
A. 1250 Gpm - 29.5lbs
B.1500 gpm- 42.3
D. 2000 gpm- 75.5
When is 4 inch supply hose tested
Annually
When new
Return from S & M
4 inch supply hose shall be tested?
300 feet max
300 psi
For five minutes
What form is completed for annual hose test?
F129
4 inch hose, what information shall be included when labeling the hose
Firestation, number and section number
Left to right